Siemens 5SY4504-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY4504-6 SENTRON MCB, Type B, 1P+N, 10 kA IEC/EN 60

MPN5SY4504-6
Active

Siemens SENTRON 5SY4504-6 miniature circuit breaker, 1P+N, tripping characteristic B, 10 kA (IEC/EN 60898-1) / 35 kA (IEC 60947-2), 230 V AC, 2 MW, 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4504-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4504-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY4504-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4504-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY4504-6 is a 1P+N miniature circuit breaker from the SENTRON family, tripping characteristic B, rated 10 kA breaking capacity under IEC/EN 60898-1 and 35 kA under IEC 60947-2. The 1P+N configuration switches both phase and neutral, with the neutral pole switching but not protecting — it opens the neutral when the phase trips. This is common in single-phase final subcircuits where disconnecting the neutral is required by local wiring rules. The neutral conductor switching is built in, so no separate neutral link is needed. Rated operating voltage is 230 V AC, with a maximum of 250 V in single-phase operation. Frequency is 50/60 Hz.

Width is 36 mm (2 modular units). Combined terminal at top and bottom — accepts both busbar and cable in the same clamp. Sealable (tamper-evident cover can be locked). Installable supplementary devices (auxiliary contacts, shunt trip, undervoltage release) can be added on the side.

For a maintenance spares purchaser, keeping one in the cabinet before it fails is straightforward — this is a part you can buy ahead on without worrying about a short production window.

Designed to IEC/EN 60898-1 (domestic MCB standard) and IEC/EN 60947-2 / UL1077 (industrial supplementary protector standard). Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. Mechanical service life 10,000 operating cycles typical. The dual-standard compliance means it can be used in both residential distribution boards and industrial control panels, but the UL1077 listing is as a supplementary protector — not a branch-circuit rated breaker per UL 489.

Frequently asked questions

What is the breaking capacity of 5SY4504-6?

10 kA per IEC/EN 60898-1 and 35 kA per IEC 60947-2. The higher 35 kA rating applies when the breaker is used as an industrial supplementary protector per IEC 60947-2.

What does tripping characteristic B mean?

Characteristic B trips magnetically at 3–5 times rated current. It is suited for resistive and general-purpose loads with low inrush — lighting, heaters, socket outlets. Not for motor circuits or transformers with high starting current.

Does 5SY4504-6 switch the neutral?

Yes, it is a 1P+N design that switches both phase and neutral. The neutral pole opens when the phase trips but does not provide overcurrent protection on the neutral.

Where can I buy 5SY4504-6?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time. No stock count or lead time is published here.