Siemens 5SY4504-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY4504-8 SENTRON MCB, 4A D Curve, 10kA/35kA, 2-Pole

MPN5SY4504-8
Active

Siemens SENTRON 5SY4504-8, miniature circuit breaker, 2-pole (1P+N), 4 A, D characteristic, 10 kA per EN 60898 / 35 kA per IEC 60947-2, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4504-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4504-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4504-8 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4504-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Derating and integration

Rated 4 A at 35 °C ambient, but the published derating curve drops it to 3.22 A at 60 °C — a 20% reduction. In a crowded DIN-rail enclosure with multiple breakers side by side, the internal temperature often exceeds 50 °C, so size the load circuit against the derated figure, not the 35 °C nameplate. The 2-module-width (36 mm) body snaps onto any standard DIN rail; the quick-assembly system lets you gang busbars without individual wiring. IP20 with conductors connected — fine for a dry enclosure, not for washdown zones.

Listed as current production. The 5SY4504-8 carries dual certification: IEC/EN 60898-1 for general-distribution MCB duty and IEC/EN 60947-2 plus UL 1077 for industrial control-panel use. Halogen-free and silicon-free construction. Neutral conductor switching is integrated — the 1P+N design breaks both line and neutral, which some local codes require on final subcircuits.

Frequently asked questions

What is the breaking capacity of 5SY4504-8?

10 kA per EN 60898 and 35 kA per IEC 60947-2. The higher 35 kA rating applies when the breaker is applied under the industrial standard, which is the figure to use for SCCR calculations on a control-panel nameplate.

Where can I buy the 5SY4504-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SY4504-8 drop into a panel specified for 5SY4104-7CV?

Both are 2-module (36 mm wide) SENTRON MCBs on the same DIN-rail footprint, so physical fit is identical. The difference is the tripping characteristic: 5SY4504-8 is a D curve (10–20× In), while 5SY4104-7CV is a different curve — verify the load's inrush profile before swapping.