Skip to main content
Siemens 5SY4508-5 — 1-Pole MCB (DIN Rail)

Siemens 5SY4508-5 SENTRON MCB, 1P+N, 10kA, Char A, 230VAC

MPN5SY4508-5
Active

Siemens SENTRON 5SY4508-5 miniature circuit breaker, 1P+N, 2-module, characteristic A, 10 kA (IEC 60898-1) / 20 kA (IEC 60947-2), 230 VAC, 60 VDC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY4508-5 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry

Electrical & Protection

5SY4508-5 — Electrical & Protection
ParameterValue
Tripping characteristic classA
Overvoltage categoryIII

Mounting & Connection

5SY4508-5 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes

Environmental

5SY4508-5 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY4508-5 — SENTRON MCB for panel builders and spares buyers

The Siemens 5SY4508-5 is a 1P+N miniature circuit breaker from the SENTRON series, switching both phase and neutral in a two-module (36 mm wide) package. It carries characteristic A — the fast-trip curve that opens within a few cycles on moderate overloads, suited for protecting semiconductor circuits, control transformers, or sensitive loads where a B-curve would let too much energy through before tripping. Rated breaking capacity is 10 kA per IEC 60898-1 and 20 kA per IEC 60947-2 at 230 VAC, with a DC rating of 15 kA at 60 V per IEC 60947-2. Under UL 1077 it carries 5 kA — enough for most North American supplementary-protection applications. The 76 mm depth (70 mm installation depth) fits standard DIN-rail enclosures with room for wiring. Lifecycle status is current production, so this is a straightforward BOM-line fill — no last-time-buy scramble. Sourced and quoted to order through independent distribution; availability and current pricing confirmed at quote time.

What the ratings mean for fit

Characteristic A trips at 2–3× rated current — faster than the more common B (3–5×) or C (5–10×) curves. That matters when the load is a rectifier input, a UPS bypass, or a control-circuit supply where a short spike from a transformer inrush could nuisance-trip a slower breaker. The 10 kA SCCR at 230 VAC (IEC 60898-1) means it safely interrupts faults up to that level without cascading upstream; the 20 kA rating under IEC 60947-2 gives additional headroom for industrial panel designs that spec to the higher standard. The 1P+N design (two poles, one protected phase plus switched neutral) is common in single-phase final subcircuits where the neutral must be disconnected for isolation. Neutral conductor switching is confirmed, so the breaker opens both poles simultaneously. Rated for pollution degree 3 and overvoltage category III — standard for fixed-installation distribution boards in industrial environments. The IP20 rating (with connected conductors) is typical for enclosed panel mounting; no washdown rating, so keep it behind a gland plate.

Panel integration and environment

Mounts on DIN rail via the quick-assembly system — snaps on, no tools. Two modular width units (36 mm) occupy two slots in a standard distribution board. Any mounting position is allowed, which simplifies layout in tight enclosures. Ambient temperature range is -40 to 75 °C, with humidity derating above 55 °C: max 95% RH at 55 °C, 55% at 70 °C, 35% at 75 °C. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — enough for machine-mounted panels but not for direct engine mounting without additional damping. Sealable design (provision for a lead seal or lockout tag) supports lockout/tagout procedures. Halogen-free and silicon-free construction matters for clean-room or high-reliability environments where outgassing could contaminate contacts or optics.

Compliance and documentation

Certified to IEC/EN 60898-1 (domestic-style MCB) and IEC/EN 60947-2 (industrial MCCB standard), plus UL 1077 for North American supplementary protection. CSA C22.2 No.235 also listed. The dual-standard rating means the same part can be specified for panels destined for both IEC and UL markets, simplifying BOM consolidation. The manufacturer provides the standard declaration of conformity, CE marking, and the full IEC/UL test reports. RoHS and REACH compliance documentation is available on request through the supply channel.

Frequently asked questions

Where can I buy 5SY4508-5 and get a price?

Sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

Will 5SY4508-5 drop into a panel specified around 5SY4116-7CV?

Both are 2-module (36 mm wide) SENTRON MCBs with the same DIN-rail footprint and 76 mm depth, so mechanical fit is identical. The deciding factor is the tripping characteristic: 5SY4508-5 is characteristic A (fast), while 5SY4116-7CV is characteristic C (industrial motor/lighting). Rewiring is not needed, but the protective curve must match the load — verify the circuit's inrush profile before swapping.

What compliance documentation does Siemens provide for 5SY4508-5?

The part carries IEC/EN 60898-1, IEC/EN 60947-2, UL 1077, and CSA C22.2 No.235 certifications. Standard CE declaration of conformity, RoHS, and REACH documentation are available through the supply channel.

MPN