Siemens 5SY4508-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY4508-7 SENTRON MCB, C-Curve, 1P+N, 10kA/20kA

MPN5SY4508-7
Active

Siemens SENTRON 5SY4508-7 miniature circuit breaker, C characteristic, 1P+N, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 230 V AC, 60 V DC, 2 MW, halogen-free.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY4508-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry

Electrical & Protection

5SY4508-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII

Mounting & Connection

5SY4508-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes

Environmental

5SY4508-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens SENTRON 5SY4508-7 is a 1P+N miniature circuit breaker with a C tripping characteristic, designed for branch-circuit protection in industrial control panels and distribution boards. It switches the neutral conductor and occupies 2 modular width units (36 mm) on a DIN rail. The C curve means it trips between 5 and 10 times rated current — the standard choice for moderate inrush loads like small motors, contactors, and lighting banks where you need selectivity against nuisance trips.

Breaking capacity — what the ratings mean

This breaker carries two breaking-capacity ratings because it's certified under both product and industrial standards. Per EN 60898 (the household / commercial standard) it's rated 10 kA at 230 V AC. Per IEC 60947-2 (the industrial standard for panel builders) it's rated 20 kA at 230 V AC, and 15 kA at 60 V DC. For UL 1077 / CSA C22.2 No. 235 applications it's rated 5 kA. The 20 kA figure is the one that matters for most industrial panels — it tells you this breaker can safely interrupt a fault up to 20 kA without welding its contacts or rupturing the case, which is enough for most secondary distribution boards fed by a transformer of 500 kVA or less.

Where it fits — panel integration

Mounts on a DIN rail via the quick assembly system in any position. Depth is 76 mm, installation depth 70 mm. IP20 with conductors connected.

Frequently asked questions

What is 5SY4508-7's listed depth?

76 mm overall; installation depth is 70 mm.

Will 5SY4508-7 drop into a panel specified around 5SY4101-7CV without rewiring?

Both are 2-module-width (36 mm) SENTRON MCBs with the same DIN-rail footprint and terminal layout, so a direct mechanical swap is possible. Verify the tripping characteristic and breaking capacity match your coordination study — the 5SY4101-7CV is a different current rating and may have a different curve.