Siemens 5SY4550-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY4550-7 SENTRON MCB, 1P+N, C-curve, 10kA IEC/EN 60

MPN5SY4550-7
Active

Siemens SENTRON 5SY4550-7 miniature circuit breaker, 1P+N, 2-module width, C tripping characteristic, 10 kA (IEC 60898-1) / 15 kA (IEC 60947-2) breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4550-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4550-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY4550-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4550-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The 10 kA breaking capacity per IEC 60898-1 and 15 kA per IEC 60947-2 tell you the part can safely interrupt fault currents up to those levels — the 60947-2 figure is the one to use when the breaker is applied in an industrial panel with higher prospective fault current, while the 60898-1 rating covers the residential/commercial installation standard. Both are verified, so you don't have to guess which standard governs your application.

The 5SY4550-7 occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm — standard 1P+N MCB footprint that drops into any SENTRON distribution board or industrial enclosure. The quick assembly system means it snaps onto the rail without tools and the combined terminal top/bottom accepts both busbar and conductor connections. IP20 with connected conductors is the protection class, so it's intended for enclosed panel mounting, not exposed washdown areas.

The breaker is certified to IEC / EN 60898-1 and IEC / EN 60947-2, and also carries UL 1077 recognition — that three-standard coverage means it's accepted in European, UK, and North American installations. The sealable design allows the panel builder to lock the toggle position after commissioning, preventing unauthorized reset.

Frequently asked questions

How do I get current pricing and availability for 5SY4550-7?

Submit an RFQ through this listing. We source the part through independent distribution and confirm availability and current pricing at quote time — no automated stock figure can replace a live check against the supply channel.

Will 5SY4550-7 drop into a panel that was specified around 5SY4116-7CV without rewiring?

Both are 2-module (36 mm wide) SENTRON MCBs with the same DIN-rail footprint and terminal layout, so the mechanical fit is the same. The difference is the tripping characteristic: 5SY4550-7 is a C-curve (5-10x In), while the 5SY4116-7CV is a B-curve (3-5x In). If the original design called for B-curve magnetic trip thresholds, swapping to C-curve may cause nuisance trips on high-impedance faults or fail to coordinate with downstream devices. Check the branch circuit's inrush profile before substituting.

What compliance documentation does this brand provide for 5SY4550-7?

The breaker carries IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 certifications. It is halogen-free and silicon-free. Standard documentation includes a declaration of conformity covering the applicable EU directives (Low Voltage Directive, EMC) and the manufacturer's test certificates for the breaking capacity ratings.