Siemens 5SY4601-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY4601-8 SENTRON MCB, D Curve, 3P+N, 10 kA

MPN5SY4601-8
Active

Siemens SENTRON 5SY4601-8 miniature circuit breaker, D characteristic, 3P+N poles, 400 V AC, 10 kA (EN 60898-1) / 35 kA (IEC 60947-2), 4 MW units, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4601-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4601-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY4601-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4601-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4601-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4601-8 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.1 W

Product details

That D curve means it tolerates the inrush of motor starters, transformers, or welding equipment — magnetic trip threshold is 10–20× rated current, so nuisance trips on high-inductive loads stay off the board. Ambient range -40 to 75 °C, with humidity derating above 55 °C: 95% RH up to 55 °C, 55% up to 70 °C, 35% up to 75 °C. Vibration resistance per IEC 60068-2-6 at ±1 mm / 5–25 Hz and 50 m/s² / 25–150 Hz.

The 5SY4601-8 carries three breaking-capacity ratings under separate standards: 10 kA per EN 60898-1 (the MCB standard for household and similar installations), 35 kA per IEC 60947-2 (the industrial circuit-breaker standard), and 5 kA per UL 1077 / CSA C22.2 No.235. The D characteristic (10–20× In magnetic trip) is the right choice for motor branch circuits, welding receptacles, or any load with a high inrush-to-running ratio.

Four modular-width units (72 mm) on DIN rail. Neutral conductor is switched internally — no separate neutral bar required for the outgoing circuit. Sealable to prevent tamper. Halogen-free and silicon-free construction, suitable for clean-room or food-beverage panel environments where outgassing must be controlled. Suitability flagged for mechanical engineering and industry.

Frequently asked questions

Where can I buy 5SY4601-8 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time and price.

What is the difference between 5SY4601-8 and 5SY4304-7CV?

The 5SY4304-7CV is a 4-pole C-curve MCB (magnetic trip 5–10× In), while the 5SY4601-8 is a 3P+N D-curve (10–20× In). The D curve is specified for motor and transformer loads with higher inrush. Both are 4-module SENTRON units on the same DIN-rail footprint, so mechanical fit is identical — the decision is the trip characteristic and neutral switching (5SY4601-8 switches neutral; check if 5SY4304-7CV does).

What compliance documentation does Siemens provide for 5SY4601-8?

The MCB is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No.235. It is halogen-free and silicon-free. Standard RoHS and REACH declarations are available from Siemens on request.