Skip to main content
Siemens 5SY4604-8CC11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4604-8CC11 SENTRON MCB, 4A D-curve 4-pole 10kA

MPN5SY4604-8CC11

Siemens SENTRON 5SY4604-8CC11 miniature circuit breaker, 4 A, D characteristic, 4-pole (3P+N), 10 kA breaking capacity at 400 V AC, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4604-8CC11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4604-8CC11 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC4 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4604-8CC11 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY4604-8CC11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4604-8CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4604-8CC11 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4604-8CC11 is a SENTRON miniature circuit breaker rated 4 A with a D tripping characteristic, 4-pole configuration (3P+N), and a 10 kA breaking capacity at 400 V AC. The D-curve tolerates high inrush currents without nuisance tripping while clearing faults up to 10 kA. The neutral pole is switched, and the unit is sealable for tamper-proof installations.

The 4 A D-curve rating protects circuits feeding inductive loads where the starting surge can be high. The 4-pole 3P+N design switches all three phases and the neutral. Terminal torque spec is 2.5–3.5 N·m. IP20 with connected conductors.

Frequently asked questions

What is the closest functional second-source to 5SY4604-8CC11?

The 5SY6602-8 is a functional peer in the same SENTRON family, but verify the tripping characteristic and pole count match your application — the 5SY4604-8CC11 is a 4 A D-curve 4-pole unit, while the peer may differ in current rating or poles. Panel fit (DIN rail, same width units) is compatible, but always confirm the specific ratings before substituting.

What is 5SY4604-8CC11's listed depth?

The depth is 76 mm, with an installation depth of 70 mm.

What wire sizes does 5SY4604-8CC11 accept?

It accepts solid and stranded conductors from 0.75 mm² up to 35 mm².

What compliance documentation does Siemens provide for 5SY4604-8CC11?

The part carries a railway design designation and is halogen-free and silicon-free. Standard Siemens declarations (CE, UKCA) apply per the SENTRON series. For specific RoHS/REACH certificates or UL listing status, request the manufacturer's declaration at quote time.

MPN
5SY4604-8CC11