Siemens 5SY4605-7CC11 — 4-Pole MCB (DIN Rail)

Siemens 5SY4605-7CC11 SENTRON MCB, 4P C 0.5A, 10kA

MPN5SY4605-7CC11

Siemens SENTRON miniature circuit breaker, 4-pole (3P+N), C-curve, 0.5 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC, designed for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4605-7CC11 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4605-7CC11 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC0.5 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4605-7CC11 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089810 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY4605-7CC11 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4605-7CC11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4605-7CC11 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

What the ratings mean for your panel

The Siemens 5SY4605-7CC11 is a SENTRON miniature circuit breaker — 4-pole (3P+N), C-curve, rated 0.5 A at 400 V AC. The C-curve means it trips between 5 and 10 times rated current, so it handles moderate inrush from small motor starters or transformer banks without nuisance tripping, but clears a hard short fast. The 10 kA breaking capacity per EN 60898 tells you it can safely interrupt a fault current up to 10 kA at the rated voltage — standard for sub-distribution boards in industrial and railway installations. At 0.5 A, this is sized for control transformers, signal circuits, or auxiliary loads, not main feeders. Rated for AC only, with a maximum DC voltage of 72 V. Overvoltage category III and pollution degree handled by the IP20 enclosure (with conductors connected). The wide ambient range, -40 °C to +75 °C, takes the radiant heat near mill drives or furnace zones — a rolling-mill environment where ordinary commercial-temp breakers drift their trip curve. Mounting position is any, and the quick-assembly system snaps onto standard DIN rail.

Frequently asked questions

Will 5SY4605-7CC11 drop into a panel specified around 5SY4310-7CV without rewiring?

Both are SENTRON 4-pole MCBs on the same DIN-rail footprint, so they share the same mounting and busbar pitch. The difference is rating: 5SY4605-7CC11 is a 0.5 A C-curve; 5SY4310-7CV is a different rating. Check your circuit's load current — if the spec calls for 0.5 A, this is a direct drop-in. If the original was a higher amp rating, this breaker will trip on the load.