Siemens 5SY4606-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY4606-6 SENTRON MCB, B-Curve 3P+N, 10 kA IEC 60898

MPN5SY4606-6
Active

Siemens SENTRON, Miniature circuit breaker, 5SY4606-6, B-curve, 3P+N, 4-pole, 10 kA (EN 60898) / 35 kA (IEC 60947-2), 400 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4606-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4606-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY4606-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4606-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4606-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4606-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.1 W

Product details

The 5SY4606-6 is a Siemens SENTRON miniature circuit breaker in a 3P+N four-pole configuration — three protected phases plus a switched neutral. Rated operational voltage is 400 V AC (440 V max multi-phase), with a DC rating of 60 V (72 V max). The neutral is switched for full isolation on all four poles.

The combined top and bottom terminals let you feed from either end without reconfiguring the busbar. Pollution degree 3 means it tolerates conductive dust and humidity typical of factory floors. The humidity derating curve caps relative humidity at 95% up to 55 °C, then drops to 35% at 75 °C — relevant if the panel sits near a heat source. Temperature range spans -40 to 75 °C, so it works in cold storage or hot machine cabinets without derating the thermal-magnetic trip.

Approvals cover IEC/EN 60898-1 for general distribution, IEC/EN 60947-2 for industrial switchgear, and UL 1077 for North American supplementary protection.

Frequently asked questions

Will the 5SY4606-6 drop into a panel specified around the 5SY4140-7?

Yes — same 4-module width (72 mm), same DIN-rail mounting, same 3P+N pole configuration. The 5SY4606-6 has a higher interrupting rating (35 kA vs the 5SY4140-7's lower value), so it is electrically upward-compatible. No rewiring or busbar change needed.

MPN
5SY4606-6