Siemens 5SY4608-5 — 4-Pole MCB (DIN Rail)

Siemens 5SY4608-5 SENTRON MCB, 4P, 8A, Char A, 10kA

MPN5SY4608-5
Active

Siemens SENTRON 5SY4 series, miniature circuit breaker, 4-pole (3P+N), 8 A rated, tripping characteristic A, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 400 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4608-5 — Identification
ParameterValue
Type / order code5SY4
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4608-5 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC8 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4608-5 — Protection
ParameterValue
Tripping characteristic (trip curve)A
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY4608-5 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY4608-5 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4608-5 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

What this 4-pole 8 A MCB does for a panel

The Siemens 5SY4608-5 is a 4-pole miniature circuit breaker from the SENTRON 5SY4 series, rated 8 A at 400 V AC with a tripping characteristic A. That characteristic A means it trips instantaneously at 2 to 3 times rated current — built for protecting semiconductor circuits or long cable runs where standard B or C curves would allow too much energy through before opening. The 4-pole (3P+N) configuration switches all three phases and the neutral, so it's the right fit for a three-phase subfeed where you want neutral protection and isolation in one unit. It snaps onto a DIN rail via the quick assembly system, occupies 4 width units (72 mm), and accepts solid or stranded conductors from 0.75 up to 35 mm² at both top and bottom combined terminals — enough cross-section for a 6 mm² feed and a 10 mm² loop-through if the panel layout needs it.

Breaking capacity — which standard governs your install

This breaker carries three interrupting ratings depending on the standard you're designing to: 10 kA per EN 60898 (the household / commercial standard), 20 kA per IEC 60947-2 (the industrial standard), and 5 kA per UL 1077 / CSA C22.2 No.235 for North American supplementary protection. That's enough headroom for most machine-level distribution boards fed from a transformer in the 100–200 kVA range.

Mounting and wiring — what the panel builder needs

Each terminal accepts solid or stranded copper from 0.75 mm² up to 35 mm², which covers everything from a 1.5 mm² control circuit to a 10 mm² feeder. The installation depth behind the panel is 70 mm (76 mm overall depth including the front of the housing). Sealable with a lead or wire seal if the application requires tamper-proofing. Ambient temperature range is -40 to +70 °C, with humidity derating above 55 °C — max 95% RH at 55 °C, dropping to 55% at 70 °C.

Frequently asked questions

What is the interrupting rating of 5SY4608-5?

It is rated 10 kA per EN 60898, 20 kA per IEC 60947-2 at 400 V AC, and 5 kA per UL 1077 / CSA C22.2 No.235. For DC circuits, it is rated 15 kA per IEC 60947-2 at a maximum of 72 V DC.

What conductor sizes does the 5SY4608-5 accept?

The combined top and bottom terminals accept solid or stranded copper conductors from 0.75 mm² up to 35 mm².

Where can I buy 5SY4608-5?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for 5SY4608-5?

The breaker is designed to EN 60898 and IEC 60947-2, and carries a UL 1077 / CSA C22.2 No.235 rating for North America. The housing is halogen-free and silicon-free.

MPN
5SY4608-5