Siemens 5SY4613-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY4613-6 SENTRON MCB, 4P B-Curve 13A 10kA

MPN5SY4613-6
Active

Siemens SENTRON, miniature circuit breaker, 5SY4613-6, 4-pole B-curve, 13 A at 35°C, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4613-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4613-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4613-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY4613-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4613-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY4613-6 is a 4-pole (3P+N) SENTRON miniature circuit breaker with B-curve tripping characteristic, rated 13 A at 35°C and 400 V AC.

Rating so-what and deployment context

The B-curve characteristic means this MCB handles loads without nuisance tripping on moderate inrush — think resistive heaters, lighting banks, and control transformers — but it's not for motor starts or heavy inductive kicks where a C or D curve would be needed. The 10 kA (EN 60898) and 20 kA (IEC 60947-2) breaking capacities cover most panelboard fault scenarios; the higher 20 kA figure under IEC 60947-2 is what matters for industrial switchgear where prospective fault current can be stiffer. The 4-pole 3P+N configuration with combined terminals top and bottom simplifies wiring in a 3-phase plus neutral distribution board — one conductor per pole, no separate neutral bar needed. IP20 with connected conductors is standard for enclosed panels; keep the gland plate sealed.

Thermal derating and environment

Rated current drops with ambient temperature: 13 A at 35°C, 12.22 A at 45°C, 11.95 A at 50°C, 11.67 A at 55°C, 11.39 A at 60°C. The -40°C to 75°C operating range covers outdoor cabinets in cold climates and warm machinery sheds.

Frequently asked questions

What is the breaking capacity of 5SY4613-6?

10 kA per EN 60898 and 20 kA per IEC 60947-2, both at 400 V AC.

Will 5SY4613-6 drop into a panel specified for 5SY6613-8?

Both are 4-module-wide SENTRON MCBs on the same DIN-rail footprint, so mechanical fit is the same. The 5SY6613-8 is an 8 A B-curve; the 5SY4613-6 is a 13 A B-curve. As long as the ampacity matches the circuit design, it swaps in without rewiring.

Where can I buy 5SY4613-6 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.