Skip to main content
Siemens 5SY4614-7 — Miniature Circuit Breakers (MCB)

Siemens 5SY4614-7 SENTRON MCB, 4-Pole C-Curve 0.3A, 10kA

MPN5SY4614-7
Active

Siemens SENTRON 5SY4614-7, 4-pole (3P+N) miniature circuit breaker, C tripping characteristic, 0.3 A at 35 °C, 10 kA (EN 60898) / 35 kA (IEC 60947-2), 400 V AC, 4 MW.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4614-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SY4614-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens SENTRON 5SY4614-7 is a 4-pole (3P+N) miniature circuit breaker with a C tripping characteristic, rated 0.3 A at 35 °C and 400 V AC.

The 0.3 A rating at 35 °C is the continuous current the breaker carries without tripping; derate to 0.29 A at 40 °C, 0.28 A at 45 °C, 0.27 A at 50 °C, 0.26 A at 55 °C, and 0.25 A at 60 °C if the panel ambient runs warm. The 10 kA SCCR per EN 60898 is the standard for final circuits in residential and commercial distribution boards; the 35 kA per IEC 60947-2 applies when the breaker is used in industrial switchgear where higher prospective fault currents are possible.

Panel integration

Halogen-free and silicon-free construction suits environments where outgassing must be minimized — clean rooms, medical, or telecom shelters.

Frequently asked questions

Where can I buy 5SY4614-7 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 5SY4614-7?

10 kA per EN 60898 for standard final-circuit duty, and 35 kA per IEC 60947-2 for industrial switchgear applications. The higher figure gives fault-current headroom where the upstream supply can deliver more than 10 kA.

What is the width of 5SY4614-7?

72 mm, which is 4 modular width units on a standard DIN-rail panel.

Will 5SY4614-7 drop into a panel specified around 5SY4304-7CV?

Both are 4-pole SENTRON MCBs with the same 72 mm width and DIN-rail mounting, so the physical footprint is identical. The difference is the rating: 5SY4614-7 is a 0.3 A C-curve; 5SY4304-7CV is a different rating and characteristic. Check the load current and tripping curve before substituting.

MPN
5SY4614-7