Siemens 5SY4616-8CC — 4-Pole MCB (DIN Rail)

Siemens 5SY4616-8CC SENTRON MCB, 16A D-Curve, 4P, 10kA

MPN5SY4616-8CC

Siemens SENTRON 5SY4616-8CC, miniature circuit breaker, 3P+N, 4-pole, D characteristic, 16 A rated at 40 °C, 10 kA breaking capacity per EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4616-8CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4616-8CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY4616-8CC — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY4616-8CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4616-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4616-8CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4616-8CC is a SENTRON miniature circuit breaker (MCB) with a D tripping characteristic, rated 16 A at 40 °C, and a breaking capacity of 10 kA per EN 60898.

The D-curve (tripping characteristic class D) means the breaker tolerates high inrush currents — typically 10–20× rated current — before the magnetic trip fires. At 16 A rated current, it handles continuous loads up to that figure; derate to 15.04 A at 40 °C and 14.02 A at 50 °C, so if your panel runs hot, size up or account for the thermal drop. Breaking capacity of 10 kA at 400 V AC per EN 60898 means it can safely interrupt a fault current up to 10,000 A without welding contacts or rupturing the case. Under UL 1077 the rating drops to 5 kA — if your job spec calls for UL listing, that lower figure governs the available fault current the breaker can see.

Frequently asked questions

What is the breaking capacity of 5SY4616-8CC?

10 kA per EN 60898 at 400 V AC, and 5 kA per UL 1077 / CSA C22.2 No.235.

Where can I buy 5SY4616-8CC?

This part is available to order through independent distribution. Submit an RFQ for current availability and pricing.

What is the difference between 5SY4616-8CC and 5SY7210-7CC?

The 5SY7210-7CC is a different pole configuration and rating — verify your BOM line against the 5SY4616-8CC's 4-pole, 16 A, D-curve specs before substituting. The two are not direct drop-in replacements without checking the circuit requirements.