Siemens 5SY4620-7CV — 4-Pole MCB (DIN Rail)

5SY4620-7CV C-Curve MCB, 20 A 4-Pole, 15 kA IEC 60947-2

MPN5SY4620-7CV

Siemens 5SY4620-7CV, 4-pole C-curve miniature circuit breaker, 20 A rated at 35 °C, 15 kA breaking capacity per IEC/EN 60947-2, 72 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4620-7CV — Identification
ParameterValue
Application suitabilityMechanical engineering / industry
5SY4620-7CV — Ratings
ParameterValue
Number of poles4
Pole configuration3+N
Rated voltage, AC (multi-phase)440 V
5SY4620-7CV — Protection
ParameterValue
Tripping characteristic (trip curve)C
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4620-7CV — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4620-7CV — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4620-7CV — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.7 W

Product details

The Siemens 5SY4620-7CV is a 4-pole (3+N) miniature circuit breaker with C-curve tripping characteristic, rated 20 A at 35 °C and carrying a 15 kA breaking capacity per IEC/EN 60947-2. Rated operating voltage is 440 V AC multi-phase, with a maximum DC operating voltage of 72 V. The breaker is designed for mechanical engineering and industrial environments, accepting supply from any position and mountable in any orientation via the quick-assembly system.

The 20 A rating holds at 35 °C ambient. At 40 °C the breaker derates to 18.54 A, at 50 °C to 16.9 A, and at 55 °C to 16.08 A. This matters for panels with high internal heat rise — if the breaker sits next to transformers or drives, use the 50 °C column to size the branch. The surrounding humidity limit is 95% at 55 °C, tapering to 35% at 75 °C. Temperature range spans -40 °C to 75 °C, with vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Integration notes

The neutral pole is switched (3+N design).

Rated frequency is 50/60 Hz. The part carries the designation letter 'F' per both EN 61346-2 and IEC 81346-2 for circuit-breaker function identification in schematics. That is standard for DIN-rail MCBs; no washdown rating here.

Frequently asked questions

What does the 15 kA breaking capacity mean for a 400 V panel?

The 15 kA rating per IEC 60947-2 means the breaker can safely interrupt a fault current up to 15 kA at the rated voltage. That is sufficient for most industrial sub-distribution boards fed by a transformer in the 630 kVA to 1000 kVA range, assuming the prospective short-circuit current at the breaker terminals does not exceed 15 kA.

Where can I buy the 5SY4620-7CV and how is it quoted?

The 5SY4620-7CV is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures are published here.

Will the 5SY4620-7CV drop into a panel specified around a 5SY4332-7CV without rewiring?

Both are 4-pole C-curve MCBs in the same 5SY series, sharing the same 72 mm width and DIN-rail mounting. The difference is the current rating — the 5SY4620-7CV is 20 A, while the 5SY4332-7CV is a different rating. If the branch load is 20 A, the 5SY4620-7CV is a direct mechanical fit; the wiring and busbar connection are identical. Verify the load current before swapping — the C-curve and pole count match.