Siemens 5SY4620-8CV — 4-Pole MCB (DIN Rail)

5SY4620-8CV 4P MCB, D Curve, 20 A, 15 kA IEC 60947-2

MPN5SY4620-8CV

Siemens 5SY4620-8CV, 4-pole miniature circuit breaker, D characteristic, 20 A rated current, 15 kA breaking capacity per IEC 60947-2, 4 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4620-8CV — Identification
ParameterValue
Application suitabilityMechanical engineering / industry
5SY4620-8CV — Ratings
ParameterValue
Number of poles4
Pole configuration3+N
Rated voltage, AC (multi-phase)440 V
5SY4620-8CV — Protection
ParameterValue
Tripping characteristic (trip curve)D
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4620-8CV — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4620-8CV — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4620-8CV — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.6 W

Product details

The 5SY4620-8CV is a 4-pole miniature circuit breaker with a D tripping characteristic, rated 20 A at 35 °C and carrying a 15 kA breaking capacity per IEC 60947-2. The 4-pole design with switched neutral (3+N) suits three-phase four-wire systems where you need to break all live conductors on a fault. Mounting position is unrestricted, and the quick-assembly system speeds rail installation.

The 15 kA breaking capacity at 440 V AC (multi-phase) per IEC 60947-2 is the key selectivity number. In a panel with a 25 kA prospective short-circuit current, you'd need a current-limiting upstream device — this breaker alone won't clear that. The D curve's magnetic trip at 10–20× In (200–400 A for the 20 A frame) is what makes it the go-to for motor branch circuits; a 7.5 kW motor on a 20 A D-curve MCB holds the start and trips on a locked-rotor event. Temperature derating matters in a warm panel. At 35 °C it's a full 20 A; at 40 °C it drops to 18.54 A, at 50 °C to 16.9 A, and at 55 °C to 16.08 A. If your panel ambient hits 50 °C, that 20 A breaker is effectively a 17 A device — size up if the continuous load is near the nameplate. The humidity limits follow a similar curve: max 95% RH up to 55 °C, then derating to 35% at 75 °C. The vibration resistance (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz per IEC 60068-2-6) covers the typical shake on a machine-mounted panel.

The breaker is certified to IEC / EN 60947-2, the standard for low-voltage switchgear and controlgear. The functional designation per IEC 81346-2 and EN 61346-2 is F — protective device. This is the same compliance package the brand provides for the entire 5SY series; no separate UL or CSA listing is stated in the spec record.

Frequently asked questions

How do I get current pricing and availability for 5SY4620-8CV?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What is 5SY4620-8CV's listed depth (76 mm) on this component line?

The overall depth is 76 mm, with an installation depth of 70 mm into the panel.

What is 5SY4620-8CV's listed width (72 mm) on this component line?

The width is 72 mm, which corresponds to 4 modular width units on a standard DIN rail.

Will 5SY4620-8CV drop into a panel that was specified around 5SY4332-7CV without rewiring?

Both are 4-pole DIN-rail MCBs with the same 72 mm width (4 MW), so the mechanical fit is identical. The difference is the tripping characteristic and rating: 5SY4620-8CV is a 20 A D curve; the 5SY4332-7CV is a lower-current C curve. If the panel's branch circuit calls for a 20 A D curve, this is a direct swap. If the original spec was a different rating or curve, the breaker will physically fit but the protection coordination changes.

What compliance documentation does this brand provide for 5SY4620-8CV (RoHS, REACH, UL, IEC)?

The breaker is certified to IEC / EN 60947-2 and carries the halogen-free and silicon-free declarations. No separate UL or CSA listing is stated in the spec record. RoHS and REACH compliance is standard for the brand's current-production 5SY series but is not explicitly listed in this part's spec fields.