Skip to main content
Siemens 5SY4632-7CV — 4-Pole MCB (DIN Rail)

Siemens 5SY4632-7CV MCB, 4P C-32 A 15 kA IEC 60947-2

MPN5SY4632-7CV

Siemens 5SY4632-7CV, 4-pole miniature circuit breaker, C-curve, 32 A rated, 15 kA breaking capacity per IEC/EN 60947-2, 440 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4632-7CV — Identification
ParameterValue
Application suitabilityMechanical engineering / industry
5SY4632-7CV — Ratings
ParameterValue
Number of poles4
Rated current (In), AC32 A
Rated voltage, AC (multi-phase)440 V
5SY4632-7CV — Protection
ParameterValue
Tripping characteristic (trip curve)C
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4632-7CV — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4632-7CV — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4632-7CV — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4632-7CV is a 4-pole miniature circuit breaker with C-curve tripping characteristic, rated 32 A at 35 °C and 440 V AC multi-phase operation. It carries a 15 kA breaking capacity per IEC/EN 60947-2, making it suitable for branch-circuit protection in industrial control panels and distribution boards where the fault level stays under that threshold.

Ratings and what they mean for fit

The C-curve means the magnetic trip operates at 5 to 10 times rated current — standard for motor circuits, transformers, and lighting loads with moderate inrush. At 32 A it handles a 7.5 kW three-phase motor at 400 V without nuisance tripping on startup. Breaking capacity of 15 kA at 440 V AC is the maximum fault current the breaker can safely interrupt. Temperature derating is published: 32 A at 35 °C, 30.24 A at 40 °C, 29.31 A at 45 °C, 28.4 A at 50 °C, 27.36 A at 55 °C (–). If the breaker lives in a non-air-conditioned enclosure, size up one frame or account for the drop at your ambient. Neutral conductor switching is built in — the fourth pole switches the neutral, not just the phases. That matters for TN-S or TT systems where the neutral must be isolated when the breaker opens.

Mounting and panel integration

Snap-on mounting to 35 mm DIN rail per the quick assembly system. Occupies 4 modular width units — 72 mm wide. Depth behind the panel is 70 mm; overall depth 76 mm. Mounting position any, so vertical or horizontal busbars both work. IP20 with connected conductors — protected against finger contact but not water ingress. Fine for enclosed distribution boards; not for washdown environments. Combined terminal top and bottom accept both busbar and cable entry without swapping parts. Sealable for lockout/tagout compliance.

Environmental and compliance

Halogen-free and silicon-free construction — relevant for clean-room or sensitive electronic environments where outgassing can cause contact corrosion. Vibration resistance tested per IEC 60068-2-6: ±1 mm at 5 to 25 Hz, 50 m/s² at 25 to 150 Hz. Mechanical service life 10,000 switching cycles typical. Overvoltage category III, pollution degree 3 — suitable for fixed installations in industrial environments with conductive pollution.

Frequently asked questions

Does 5SY4632-7CV switch the neutral?

Yes, neutral conductor switching is built in — the fourth pole isolates the neutral, not just the phases.

MPN
5SY4632-7CV