Siemens 5SY4650-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY4650-8 SENTRON MCB, 4P D-curve 50A, 10kA/15kA

MPN5SY4650-8
Active

Siemens SENTRON miniature circuit breaker, 5SY4650-8, 4-pole (3P+N), D tripping curve, 50 A rated current, 400 V AC, 10 kA / 15 kA breaking capacity, IP20.

$120.65Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4650-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4650-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4650-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-215 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY4650-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4650-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4650-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4650-8 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON series, with a D tripping curve rated at 50 A and 400 V AC. The 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2 give it headroom for industrial panel fault levels; the higher IEC figure is the one to use when coordinating with downstream MCCB or fuses in a 400 V distribution board.

If this breaker sits downstream of a larger MCCB or fuse, the let-through energy (I²t) at 15 kA is low enough that a properly sized upstream device can provide full selectivity up to that fault level. The D curve's higher magnetic threshold also helps with selective coordination against nuisance trips on motor-start transients. Environmental range is wide: -40 °C to +75 °C ambient, with humidity derating above 55 °C (max 95% RH at 55 °C, dropping to 35% at 75 °C). Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz — typical for machine-mounted panels.

Frequently asked questions

Where can I buy the 5SY4650-8?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 5SY4650-8?

10 kA per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC. The higher IEC figure is the one to use for industrial fault-level coordination.

Will the 5SY4650-8 drop into a panel specified around the 5SY7140-8CC?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint (4 MW, 72 mm wide), so mechanical fit is the same. The 5SY4650-8 is a D-curve 50 A device; the 5SY7140-8CC is a C-curve 40 A device. If the panel was wired for 40 A C-curve, swapping to a 50 A D-curve changes the overcurrent protection rating and the trip characteristic — verify the branch circuit's conductor sizing and load type before substitution.