Skip to main content
Siemens 5SY5101-7CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY5101-7CC11 SENTRON MCB, 1A C-curve, 10kA DC, rail

MPN5SY5101-7CC11

Siemens SENTRON 5SY5101-7CC11, miniature circuit breaker, 1-pole, C-curve, 1 A, 10 kA DC at 220 V, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5101-7CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SY5101-7CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY5101-7CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY5101-7CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY5101-7CC11 is a 1-pole miniature circuit breaker rated 1 A with a C-curve tripping characteristic, designed for universal current operation on DC circuits up to 220 V (250 V max) and AC circuits at 230/400 V. Its 10 kA breaking capacity at 220 V DC per IEC 60947-2 means it can safely interrupt a fault current up to that level on a DC rail without cascading upstream — critical for protecting downstream loads in a DC distribution panel.

Frequently asked questions

Where can I buy 5SY5101-7CC11 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest functional second-source to 5SY5101-7CC11?

The 5SY7140-8CC is a peer in the same SENTRON family but differs in key ratings: it is an AC-only 40 A D-curve breaker with 15 kA at 400 V AC and a lower DC max of 72 V. It will not drop into a panel specified for the 5SY5101-7CC11 without rewiring because the DC voltage rating and tripping curve are different — the 5SY7140-8CC is not a functional substitute for a 1 A DC railway circuit.

What is 5SY5101-7CC11's listed depth?

The overall depth is 76 mm, with an installation depth of 70 mm behind the panel face.

What wire sizes does 5SY5101-7CC11 accept?

The screw-type terminals accept 0.75 to 35 mm² solid or stranded copper conductors.

Will 5SY5101-7CC11 drop into a panel specified around 5SY7140-8CC without rewiring?

No. The 5SY7140-8CC is an AC-only 40 A D-curve breaker with a 72 V DC max, while the 5SY5101-7CC11 is a 1 A C-curve breaker rated for 220 V DC railway service. The footprint (18 mm width, DIN rail) is the same, but the electrical ratings and application are incompatible — rewiring and possibly a different busbar arrangement would be required.

MPN
5SY5101-7CC11