Skip to main content
Siemens 5SY5101-7KK11 — 1-Pole MCB (DIN Rail)

Siemens 5SY5101-7KK11 SENTRON MCB, 1P, C-Curve, 10kA

MPN5SY5101-7KK11

Siemens SENTRON 5SY5101-7KK11, miniature circuit breaker, 1-pole, C-curve, 10 kA breaking capacity per EN 60898, universal current AC/DC, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY5101-7KK11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityuniversal current
5SY5101-7KK11 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY5101-7KK11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5101-7KK11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It carries a DC breaking capacity of 15 kA per IEC 60947-2, which is the figure to use when specifying for DC circuits — the EN rating is the lower bound for AC applications. The C-curve (5-10x In) means it's the standard choice for protecting general-purpose loads like lighting, control transformers, and small motor circuits where moderate inrush is expected.

At 18 mm width (1 modular unit), it fits standard distribution boards and sub-panels. The combined terminal at top and bottom accepts both busbar and conductor connections, and the sealable design allows the panel builder to lock the setting against unauthorised changes.

Frequently asked questions

Where can I buy 5SY5101-7KK11 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 5SY5101-7KK11?

10 kA per EN 60898 for AC circuits, and 15 kA at DC per IEC 60947-2. The DC rating is the higher figure and applies when the breaker is used in a DC circuit up to 250 V.

What compliance documentation is available for 5SY5101-7KK11?

The breaker carries an IP20 protection class with connected conductors, is halogen-free and silicon-free, and is designed for overvoltage category III with pollution degree 3. The manufacturer provides standard CE declaration and product documentation for railway applications per the design designation.

MPN
5SY5101-7KK11