Siemens 5SY5102-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY5102-6 SENTRON MCB, B-Curve 2A 1P 10kA

MPN5SY5102-6
Active

Siemens SENTRON 5SY5102-6, miniature circuit breaker, B-curve, 2 A rated, 1-pole, 10 kA breaking capacity per IEC/EN 60898-2 and UL1077, 1-module width (18 mm).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY5102-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityuniversal current
5SY5102-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY5102-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5102-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY5102-6 is a SENTRON miniature circuit breaker, B-curve, rated 2 A at 230/400 V AC with a 10 kA breaking capacity per IEC/EN 60898-2 and UL1077. One-pole design, single-module width (18 mm), and a depth of 76 mm — fits standard DIN-rail enclosures without overhang. Tripping characteristic B means it holds 3–5× rated current for short overloads, then trips fast on a hard short; that's the go-to curve for general-purpose lighting and receptacle circuits where you want nuisance-free operation from inrush but still need fast fault clearing.

The 2 A rating is the continuous current at 35 °C ambient; derate to 1.9 A at 40 °C, 1.8 A at 50 °C, and 1.7 A at 60 °C. The 10 kA breaking capacity at 230/400 V AC (and 10 kA DC per EN 60898-2) means it can safely interrupt a fault up to that level without welding contacts or cascading upstream. The B-curve (3–5× In magnetic trip) is the right choice for resistive loads, small lighting circuits, and control transformers where you don't want the breaker to pop on a motor's starting inrush.

Snap-on DIN-rail mount, any position. Halogen-free and silicon-free construction — important for clean-room or semiconductor-adjacent panels where outgassing can contaminate optics or contacts.

Frequently asked questions

Where can I buy 5SY5102-6 and get a price?

We source the 5SY5102-6 to order against an RFQ through independent distribution. Submit a quote request for current availability and pricing — confirmed at quote time, not a published figure.

Will 5SY5102-6 drop into a panel specified for 5SY5240-7 without rewiring?

Both are 1-pole SENTRON MCBs in 18 mm width with the same DIN-rail footprint and terminal layout, so the 5SY5102-6 is a physical drop-in. The difference is the rating: 5SY5102-6 is a 2 A B-curve; 5SY5240-7 is a 40 A C-curve. Confirm the branch-circuit load and coordination study before swapping — the breaker must match the wire size and fault current.

What compliance documentation does Siemens provide for 5SY5102-6?

The breaker is certified to IEC/EN 60898-2 and UL1077. It is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations. Pollution degree 3 and overvoltage category III are specified for industrial fixed-installation environments.

MPN