Skip to main content
Siemens 5SY5102-7 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SY5102-7 MCB, C-Curve, 1-Pole, 10kA

MPN5SY5102-7
Active

Siemens SENTRON miniature circuit breaker, 1-pole, C characteristic, 10 kA breaking capacity per IEC/EN 60898-2, 400 V AC / 220 V DC, 1 MW width, IP20.

$20.32Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5102-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityuniversal current
5SY5102-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY5102-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5102-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY5102-7 is a 1-pole miniature circuit breaker with a C tripping characteristic, rated for universal current operation (AC/DC). It breaks fault currents up to 10 kA per IEC/EN 60898-2 and 15 kA per IEC 60947-2 at DC, making it suitable for branch-circuit protection in commercial and light-industrial panels. The C-curve (5-10x In) handles moderate inrush from motor starters and lighting ballasts without nuisance trips — it's the standard choice for general-purpose loads where the start-up surge isn't extreme.

DIN-rail fit and panel integration

Occupies 1 modular width unit (18 mm) on the DIN rail, with a 70 mm installation depth and 76 mm overall depth. The quick-assembly fastening system clips onto standard 35 mm DIN rail; mounting position is unrestricted. Combined terminals top and bottom accept copper conductors — no neutral pole to land, since this is a 1-pole device without neutral switching. IP20 with connected conductors means it's protected against finger contact in a closed panel, but not against dripping water; keep it inside a gland-plated enclosure.

Breaking capacity and coordination

Rated breaking capacity of 10 kA at 400 V AC per IEC/EN 60898-2, and 15 kA at DC per IEC 60947-2. The higher DC figure matters when this breaker is used in DC auxiliary circuits — say, control power from a 220 V DC bus — where fault currents can be stiffer than the AC rating suggests. Energy limitation class 3 means it limits let-through energy enough to protect downstream wiring and connected devices in most panel layouts. Overvoltage category III and pollution degree 3 suit it for fixed installations within building distribution boards, not for outdoor or wet locations.

Sourcing and availability

The 5SY5102-7 is an active, in-production Siemens SENTRON MCB. It is sourced and quoted to order through independent distribution against an RFQ — availability and current pricing are confirmed at quote time. For BOM-freeze or project-bid quantities, submit an RFQ; the supply channel covers standard catalog volumes without lead-time surprises.

Frequently asked questions

What is the breaking capacity of the 5SY5102-7?

10 kA at 400 V AC per IEC/EN 60898-2, and 15 kA at DC per IEC 60947-2. The DC rating is higher, so check your DC fault level against the 15 kA figure if using it on a DC bus.

What compliance documentation does the 5SY5102-7 carry?

It is certified to IEC/EN 60898-2 and UL1077, halogen-free and silicon-free. Standard documentation includes CE declaration and manufacturer's test certificates per the SENTRON series.

Where can I buy the 5SY5102-7?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote to confirm availability and pricing for your quantity.

What is the difference between the 5SY5102-7 and the 5SY5240-7?

The 5SY5240-7 is a higher-current variant in the same SENTRON 5SY series. The 5SY5102-7 is a 1-pole C-curve breaker at a lower amp rating; both share the same 18 mm width, same breaking capacity class, and same DIN-rail footprint. If your BOM specifies the 5SY5240-7, the 5SY5102-7 will not drop in without checking the load current — the amp rating is the deciding factor, not the mechanical fit.

MPN
5SY5102-7