Siemens 5SY5104-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY5104-6 SENTRON MCB, 1P, B Curve, 4 A, 10 kA, 1 MW

MPN5SY5104-6
Active

Siemens SENTRON 5SY5104-6, 1-pole miniature circuit breaker, B tripping characteristic, 4 A rated current, 10 kA breaking capacity per IEC/EN 60898-2 and UL1077, 1 modular width unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5104-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityuniversal current
5SY5104-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY5104-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5104-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What this MCB does

The Siemens 5SY5104-6 is a 1-pole miniature circuit breaker from the SENTRON series, rated 4 A with a B tripping characteristic. It breaks fault currents up to 10 kA per IEC/EN 60898-2 and UL1077, so it clears a short circuit before downstream wiring or equipment takes thermal damage. The single modular width (18 mm) snaps onto a DIN rail via the quick-assembly system and occupies one slot in a distribution board — no extra space for neutral switching, since this pole does not switch the neutral conductor.

B-curve tripping and thermal derating

The B characteristic trips between 3 and 5 times rated current — the standard choice for resistive and general-purpose loads where inrush is modest. At 35 °C ambient the breaker holds 4 A continuously; at 40 °C it derates to 3.76 A, at 50 °C to 3.5 A, and at 60 °C to 3.22 A (–). That derating curve means a panel running at 50 °C ambient should treat this as a 3.5 A device, not 4 A, to avoid nuisance tripping on a warm bus.

Mounting and integration

The 5SY5104-6 mounts in any position on a DIN rail. Installation depth is 70 mm; overall depth is 76 mm. Combined terminals at top and bottom accept wiring without reorienting the breaker. The housing is halogen-free and silicon-free — relevant for panels in clean rooms or environments where outgassing must be minimized. Sealable with a lockable cover if the specification requires tamper-proofing. Pollution degree 3 and overvoltage category III suit it for fixed installations inside an enclosure, not for wet or outdoor locations (IP20 only with connected conductors).

Frequently asked questions

What compliance documentation does Siemens provide for 5SY5104-6?

The breaker is certified to IEC/EN 60898-2 and UL1077. It is halogen-free and silicon-free, which supports RoHS and REACH compliance statements from the manufacturer.

MPN
5SY5104-6