Skip to main content
Siemens 5SY5104-7CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY5104-7CC11 SENTRON MCB, 1P C 4A DC Railway

MPN5SY5104-7CC11

Siemens SENTRON 5SY5104-7CC11, miniature circuit breaker, 1-pole, C-curve, 4 A, 10 kA DC at 220 V, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5104-7CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityRailway
5SY5104-7CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY5104-7CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5104-7CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY5104-7CC11 is a 1-pole miniature circuit breaker rated for 4 A with a C tripping characteristic, designed for DC operation up to 250 V and a breaking capacity of 10 kA at 220 V DC per IEC 60947-2. The C-curve means it trips at 5 to 10 times rated current — standard for moderate inrush loads like control transformers or small DC motor drives — so a 4 A unit clears a sustained 20–40 A fault quickly while ignoring brief startup spikes. This is a dedicated DC-rated breaker, not an AC-rated unit used on DC. The 10 kA interrupting rating at 220 V DC is the figure that governs fit for a DC bus or battery-backed circuit; an AC-only breaker would lack the arc-quenching capability for DC faults. The part also carries a 230/400 V AC rating at 10 kA, but the DC spec is the headline here.

The 5SY5104-7CC11 is explicitly designed for railway applications — the product designation and suitability field both flag this. That means it meets the vibration and shock profile of rail environments: ±1 mm at 5 to 25 Hz and 50 m/s² at 25 to 150 Hz per IEC 60068-2-6. If you're sourcing for a locomotive auxiliary panel, signaling cabinet, or wayside power supply, this is the variant that carries the rail-specific qualification. Mounting is the standard 18 mm modular width (1 MWU) on DIN rail, with a quick-assembly fastening system and any mounting position allowed. Polarity must be observed on the DC supply connection.

Frequently asked questions

What is the breaking capacity of 5SY5104-7CC11 on DC?

The 5SY5104-7CC11 has a DC breaking capacity of 10 kA at 220 V DC per IEC 60947-2, with a maximum DC operating voltage of 250 V.

Will 5SY5104-7CC11 drop into a panel specified around 5SY4116-7CV?

Physically yes — both are 18 mm wide, 76 mm deep, 90 mm tall, and mount on DIN rail with the same quick-assembly system. The 5SY4116-7CV is an AC-only breaker (230 V AC, 15 kA) for mechanical engineering/industry, while the 5SY5104-7CC11 is a DC-rated breaker for railway applications. They are not electrically interchangeable without verifying the circuit type.

Where can I buy 5SY5104-7CC11?

The 5SY5104-7CC11 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY5104-7CC11