Skip to main content
Siemens 5SY5106-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY5106-6 SENTRON MCB, 1P, B-Curve, 10 kA, 400 V

MPN5SY5106-6
Active

Siemens SENTRON 5SY5106-6, 1-pole miniature circuit breaker, B-curve, 10 kA (IEC/EN 60898-2), 400 V AC, 18 mm width, 1 MW.

$17.78Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5106-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityuniversal current
5SY5106-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SY5106-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5106-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

At 18 mm wide (one modular width), it snaps onto DIN rail and leaves the adjacent slots free for other breakers or accessories. The quick-assembly fastening method and combined top/bottom terminals mean you land the conductors without hunting for the right side — saves a few minutes per panel when you're wiring twenty of these.

It carries dual certification to IEC/EN 60898-2 and UL1077, so it's accepted in both IEC and North American panel builds where UL 1077 supplementary protection is recognized. Halogen-free and silicon-free construction matter for installations in clean rooms or areas with sensitive electronics.

Environmental limits and mounting

Rated for ambient temperatures from -40 °C to 75 °C, with humidity derating above 55 °C (95% RH to 55 °C, 55% to 70 °C, 35% to 75 °C). That covers outdoor enclosures in cold climates and warm electrical rooms without forced cooling. Mounts in any orientation — no derating required for horizontal or inverted positions. The 70 mm installation depth (76 mm overall) is standard for DIN-rail enclosures; verify your enclosure's internal depth if using a shallow gland plate.

DC capability and polarity

Rated for DC operation up to 220 V (250 V max) with 10 kA per EN 60898-2 and 15 kA per IEC 60947-2. The spec notes that DC polarity must be observed — the supply cord position matters for DC, while AC can be fed from either side. This matters if you're using it in a DC combiner or battery circuit where the wrong polarity could reduce arc-quenching effectiveness.

Frequently asked questions

Where can I buy the 5SY5106-6 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a binding commercial offer.

What is the 5SY5106-6's width and depth for panel layout?

Width is 18 mm (one modular unit), depth is 76 mm (70 mm installation depth). It occupies a single DIN-rail slot and fits standard enclosures with at least 70 mm internal clearance.

What compliance documentation does Siemens provide for the 5SY5106-6?

The breaker carries IEC/EN 60898-2 and UL1077 certifications. It is halogen-free and silicon-free. Standard Siemens documentation includes the declaration of conformity, CE marking, and UL recognition — request specific compliance docs with your RFQ.

MPN
5SY5106-6