Skip to main content
Siemens 5SY5116-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY5116-7CC SENTRON MCB, 16A C-Curve, 1P, 10kA DC

MPN5SY5116-7CC

Siemens SENTRON miniature circuit breaker, 5SY5116-7CC, 1-pole, 16 A (at 35 °C), C characteristic, 10 kA DC at 220 V, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5116-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY5116-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY5116-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY5116-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What this MCB is and where it fits

The Siemens 5SY5116-7CC is a SENTRON miniature circuit breaker, single-pole, with a C tripping characteristic rated at 16 A at 35 °C. It's designed for DC circuits up to 250 V maximum, with a breaking capacity of 10 kA at 220 V DC. This is a 1-module-width (18 mm) unit that snaps onto a DIN rail via the quick-assembly system. Its IP20 rating with connected conductors means it's intended for enclosed distribution boards or control cabinets — not exposed outdoor mounting. The operating temperature range spans -40 °C to 75 °C, with a derating curve that drops the continuous current from 16 A at 35 °C to 13.1 A at 55 °C.

DC ratings and what they mean for fit

The 10 kA DC breaking capacity at 220 V is the headline number for DC applications. DC arcs are harder to extinguish than AC — they have no zero-crossing — so this rating tells you the breaker can safely interrupt a fault up to 10 kA on a 220 V DC bus. The maximum operating voltage is 250 V DC, so it covers nominal 220 V DC systems with headroom. For DC circuits, polarity must be observed on the supply connection.

Integration and panel fit

Mounts in any position on a standard 35 mm DIN rail. The 18 mm width (1 modular unit) means it occupies a single slot in a distribution board. Depth is 76 mm, installation depth 70 mm — check your enclosure's door clearance if using a transparent cover. The combined top and bottom terminals accept the same conductor sizes; the breaker is sealable for tamper-proof installations. It's halogen-free and silicon-free, which matters for panels in clean-room or high-value electronics environments where outgassing can cause contact corrosion.

MPN
5SY5116-7CC