Siemens 5SY5202-7CC — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SY5202-7CC MCB, 2A C-Curve 2P DC 440V 10kA

MPN5SY5202-7CC

Siemens SENTRON 5SY5202-7CC, miniature circuit breaker, 440 V DC, 10 kA, 2-pole, C-curve, 2 A.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5202-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY5202-7CC — Electrical
ParameterValue
Number of poles2
5SY5202-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY5202-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY5202-7CC — Environmental
ParameterValue
Pollution degree3

Product details

DC-rated miniature circuit breaker for industrial control panels

At 2 A rated current, this breaker is sized for signal and control loads rather than main power distribution; it fits a 36 mm wide DIN-rail footprint (2 modular width units) and accepts auxiliary devices for remote signaling or shunt-trip functionality.

DC application and breaking capacity

The 2-pole design switches both conductors, and the manufacturer notes to observe polarity when connecting the supply — DC arcs require deliberate contact gap and arc-chamber design, which this breaker's construction addresses.

The SENTRON 5SY series is a mature, widely specified platform; PCNs are rare, but if a BOM freeze requires assurance, the manufacturer's standard documentation package (declaration of conformity, CE, RoHS, REACH) is available on request.

Panel integration and environmental limits

Snap-on mounting to DIN rail, any position. Ambient temperature range -40 °C to 75 °C, with humidity derating above 55 °C (max 95% RH at 55 °C, declining to 35% at 75 °C). Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — adequate for most industrial machinery but not for direct engine-mount applications.

Frequently asked questions

Will 5SY5202-7CC drop into a panel specified around 5SY5202-6 without rewiring?

Physically yes — both share the same 76 mm depth, 36 mm width, 90 mm height, DIN-rail mounting, and IP20 terminal layout. The functional difference is the tripping curve: 5SY5202-6 is a B-curve (faster trip on inrush), while this is a C-curve (handles higher inrush before tripping). If the original design assumed B-curve coordination, swapping to C-curve may change selective coordination with upstream breakers. Same footprint, different protection characteristic.