Skip to main content
Siemens 5SY5202-7CC12 — 2-Pole MCB (DIN Rail)

Siemens 5SY5202-7CC12 SENTRON MCB, 2A 2P C DC 440V

MPN5SY5202-7CC12

Siemens SENTRON 5SY5202-7CC12, miniature circuit breaker, 2-pole DC, 2 A, C characteristic, 440 V DC, 10 kA, for railway applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5202-7CC12 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentRailway
5SY5202-7CC12 — Electrical
ParameterValue
Number of poles2
5SY5202-7CC12 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY5202-7CC12 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY5202-7CC12 — Environmental
ParameterValue
Pollution degree3

Product details

Width is 36 mm (2 modular units), depth 76 mm, height 90 mm, with an installation depth of 70 mm. Mounts in any position via the quick-assembly system — snaps onto standard DIN rail. IP20 with connected conductors, so it lives inside a sealed enclosure on the train or in the trackside cabinet.

Frequently asked questions

What are the key ratings for 5SY5202-7CC12?

2-pole DC miniature circuit breaker, 2 A at 35 °C, C characteristic, rated 440 V DC (max 500 V DC), 10 kA breaking capacity. Designed for railway applications per EN 61346-2 type F.

Where can I buy 5SY5202-7CC12 and what is the price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SY5202-7CC12 fit a panel designed for a 5SY5250-7?

Both are 2-pole SENTRON 5SY5 series MCBs with the same 36 mm width (2 MW) and DIN-rail mounting. The 5SY5202-7CC12 is a 2 A C-curve DC railway type; the 5SY5250-7 is a higher-current variant. They share the same footprint and terminal layout — no rewiring needed for the swap, but verify the current rating and DC application match your circuit.

What compliance documentation does Siemens provide for 5SY5202-7CC12?

The part is halogen-free and silicon-free. As a Siemens SENTRON railway-series MCB, it carries CE marking and is designed to IEC/EN 60898 and IEC/EN 60947-2 standards. RoHS and REACH declarations are available from Siemens documentation for this product family.

MPN
5SY5202-7CC12