Siemens 5SY5216-6KK11 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SY5216-6KK11 MCB, 2P B 16A 10kA

MPN5SY5216-6KK11

Siemens SENTRON 5SY5216-6KK11, 2-pole B-curve miniature circuit breaker, 16 A rated at 35 °C, 10 kA breaking capacity per EN 60898, 2 MW units, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY5216-6KK11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentuniversal current
5SY5216-6KK11 — Electrical
ParameterValue
Number of poles2
5SY5216-6KK11 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY5216-6KK11 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY5216-6KK11 — Environmental
ParameterValue
Pollution degree3
5SY5216-6KK11 — Specifications
ParameterValue
Energy Limitation Class3

Product details

The Siemens SENTRON 5SY5216-6KK11 is a 2-pole miniature circuit breaker with B-curve tripping characteristic, rated 16 A at 35 °C and 10 kA breaking capacity per EN 60898. It occupies 2 modular width units (36 mm) on a DIN rail, with 76 mm depth and 70 mm installation depth — standard footprint for a 2P MCB in a distribution board. Rated for universal current (AC/DC) with 440 V DC maximum, so it handles DC control circuits as well as AC branch circuits. Breaking capacity is 10 kA at both AC (per EN 60898) and DC (per EN 60898-2). That's the standard domestic/light commercial fault level — adequate for most sub-distribution boards, but check your upstream transformer impedance if the prospective short-circuit current exceeds 10 kA.

Temperature derating and real-world current

The 16 A rating holds at 35 °C ambient. Above that, derate linearly: 15.23 A at 40 °C, 14.83 A at 45 °C, 14.43 A at 50 °C, 14 A at 55 °C, and 13.57 A at 60 °C. The -40 °C to 75 °C operating range covers cold storage and hot roof spaces.

Frequently asked questions

Where can I buy 5SY5216-6KK11 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What is the breaking capacity of 5SY5216-6KK11?

10 kA per EN 60898 for AC circuits, and 10 kA per EN 60898-2 for DC circuits. That's the standard domestic/light commercial fault level.

What compliance documentation does Siemens provide for 5SY5216-6KK11?

The product carries EN 60898 and EN 60898-2 ratings, overvoltage category III, pollution degree 3, and is halogen-free and silicon-free. Standard Siemens declarations of conformity (CE, UKCA) are available on request.

Will 5SY5216-6KK11 drop into a panel specified around 5SY5240-7?

Both are 2-pole SENTRON MCBs with the same 36 mm width and DIN-rail mounting, so the mechanical fit is identical. The difference is rating: 5SY5216-6KK11 is 16 A B-curve, while 5SY5240-7 is 40 A — check your load before swapping.