Skip to main content
Siemens 5SY5232-6KK11 — 2-Pole MCB (DIN Rail)

Siemens 5SY5232-6KK11 SENTRON MCB, 2P 32A B-Curve, 10kA

MPN5SY5232-6KK11

Siemens SENTRON 5SY5232-6KK11 miniature circuit breaker, 2-pole, 32 A, B tripping characteristic, 10 kA interrupting capacity at 400 V AC, 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY5232-6KK11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentuniversal current
5SY5232-6KK11 — Electrical
ParameterValue
Number of poles2
5SY5232-6KK11 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY5232-6KK11 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

The 10 kA interrupting capacity per EN 60898 tells you it can safely clear a fault up to 10,000 A at 400 V AC — enough for most sub-distribution boards in commercial and light industrial panels. That dual AC/DC rating is a real time-saver when you're stocking one spare for both AC lighting and DC control power in the same cabinet.

The quick-assembly mounting system snaps onto the rail without tools. Combined terminals at both top and bottom let you feed through or loop out without extra accessories.

Environmental and compliance details

Halogen-free and silicon-free construction means no corrosive off-gassing in a fault — important for panels with sensitive electronics or in clean-room adjacent areas. The surrounding temperature influence table shows derating above 55 °C: max 95% humidity at 55 °C, dropping to 55% at 70 °C and 35% at 75 °C — relevant if the breaker lives near a heat source.

Frequently asked questions

Where can I buy 5SY5232-6KK11 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the key ratings of 5SY5232-6KK11?

It is a 2-pole (2P) miniature circuit breaker rated 32 A at 400 V AC with B tripping characteristic and 10 kA interrupting capacity per EN 60898. On DC, it is rated 10 kA at 440 V per EN 60898-2, with a maximum DC voltage of 500 V.

Will 5SY5232-6KK11 drop into a panel that was specified around 5SY3132-6 without rewiring?

Both are 2-pole SENTRON MCBs in the same 36 mm width with quick-assembly DIN-rail mounting. The terminal range (0.75 to 35 mm² solid/stranded) is identical. The main difference is the tripping characteristic: the 5SY3132-6 is a C-curve, while this 5SY5232-6KK11 is a B-curve. If the original design required C-curve for motor or transformer loads, swapping to B-curve may cause nuisance tripping on inrush. For resistive or general-purpose circuits, it is a direct mechanical fit.

What compliance documentation does this brand provide for 5SY5232-6KK11?

The product is designed for railway applications and carries the SENTRON brand. Standard documentation includes a declaration of conformity to EN 60898 and EN 60898-2, as well as RoHS and REACH compliance statements available from the manufacturer.

MPN
5SY5232-6KK11