Skip to main content
Siemens 5SY5240-6 — 2-Pole MCB (DIN Rail)

Siemens 5SY5240-6 SENTRON MCB, 2-Pole, B-Curve, 10 kA, 400V

MPN5SY5240-6
Active

Siemens SENTRON 5SY5240-6, 2-pole miniature circuit breaker, B characteristic, 10 kA breaking capacity per IEC/EN 60898-2, 400 V AC, 440 V DC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5240-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentuniversal current
5SY5240-6 — Electrical
ParameterValue
Number of poles2
5SY5240-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY5240-6 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY5240-6 — Environmental
ParameterValue
Pollution degree3
5SY5240-6 — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

The 400 V AC / 440 V DC voltage rating means it can switch single-phase or three-phase loads within those limits — the DC rating is particularly relevant for control panels with 24 V or 48 V DC supplies, where the arc extinction differs from AC. This suits single-phase 230 V AC circuits or two-wire DC circuits where both poles need overcurrent protection. The IP20 rating applies only with connected conductors, so the terminals are finger-safe once wired but the busbar area is not protected against moisture; keep it inside a sealed enclosure in washdown environments.

The breaker is certified to IEC/EN 60898-2 and UL1077, covering both the IEC household-type standard and the UL supplementary protector standard. This dual certification simplifies panel approvals for equipment exported to North America and Europe. The operating temperature range spans -40 °C to 75 °C, with humidity derating above 55 °C (95% RH up to 55 °C, 55% RH up to 70 °C, 35% RH up to 75 °C). The vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz; 50 m/s² at 25–150 Hz) confirms suitability for installation on machinery or in mobile equipment panels.

Frequently asked questions

How do I get current pricing and availability for the 5SY5240-6?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest functional second-source for the 5SY5240-6?

The 5SY5240-7 is the same 2-pole B-curve breaker but with a higher breaking capacity — 15 kA per IEC/EN 60898-2 versus 10 kA on the -6. The physical footprint (2 MW, 36 mm wide) and terminal layout are identical, so it drops into the same panel position without rewiring. The -6 is the correct choice where the available fault current stays under 10 kA; the -7 covers installations with higher prospective short-circuit current.

Will the 5SY5240-6 drop into a panel specified around the 5SY5240-7 without rewiring?

Yes. Both breakers share the same 2-module-width footprint (36 mm), the same DIN-rail quick-assembly mounting, and the same terminal layout. The only difference is the breaking capacity: the -6 is rated 10 kA per IEC/EN 60898-2, the -7 is rated 15 kA. If the panel's available fault current is below 10 kA, the -6 is a direct mechanical and electrical replacement.

What compliance documentation does Siemens provide for the 5SY5240-6?

The breaker carries IEC/EN 60898-2 and UL1077 certifications. The housing is halogen-free and silicon-free. The manufacturer provides a declaration of conformity covering the applicable EU directives (Low Voltage Directive, EMC) and the UL recognition mark. RoHS and REACH compliance is standard for the SENTRON series.

MPN
5SY5240-6