Siemens 5SY5406-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY5406-7CC SENTRON MCB, 4P C-6A, 10kA DC

MPN5SY5406-7CC

Siemens SENTRON 5SY5406-7CC, 4-pole miniature circuit breaker, C tripping characteristic, 6 A rated current at 35 °C, 10 kA DC breaking capacity per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5406-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY5406-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
5SY5406-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Overvoltage categoryII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SY5406-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY5406-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

What this MCB is and where it fits

The Siemens 5SY5406-7CC is a 4-pole SENTRON miniature circuit breaker with a C-curve tripping characteristic, rated 6 A at 35 °C and carrying a 10 kA DC breaking capacity per IEC 60947-2. It snaps onto a DIN rail via the quick assembly system and occupies 4 modular width units (72 mm) in the panel. The IP20 enclosure (with connected conductors) suits it for installation inside a distribution board or control cabinet — not for wet or outdoor locations.

Ratings that decide the fit

The C-curve means the magnetic trip activates at 5 to 10 times rated current — standard for motor and transformer branch circuits where inrush is moderate. At 35 °C the breaker holds 6 A continuous; derate to 5.32 A at 40 °C, 4.95 A at 45 °C, 4.55 A at 50 °C, and 4.1 A at 55 °C (–). If the panel ambient runs above 40 °C, size the upstream load to the derated figure, not the 35 °C number. The DC breaking capacity of 10 kA at up to 1000 V DC is the headline number for DC bus or battery-string protection. That 10 kA is the maximum fault current the breaker can safely interrupt under IEC 60947-2 — if the available fault current at the panel exceeds that, you need a current-limiting upstream device or a higher-rated breaker. Operating temperature spans -40 °C to 75 °C, with humidity derating: max 95% RH up to 55 °C, dropping to 55% at 70 °C and 35% at 75 °C. Vibration resistance per IEC 60068-2-6 is ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz — fine for machine-mounted panels but not for direct engine-mount without isolation.

Panel integration notes

Mounts in any position on a DIN rail via the quick assembly system. Depth is 76 mm, with 70 mm installation depth behind the panel face. Width of 72 mm equals 4 modular units.