Skip to main content
Siemens 5SY5413-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY5413-7 SENTRON MCB, 4P C 13A 10kA AC/DC

MPN5SY5413-7
Active

Siemens SENTRON 5SY5413-7 miniature circuit breaker, 4-pole, C-curve, 13 A rated, 10 kA breaking capacity per IEC/EN 60898-2 and UL 1077, AC/DC universal current, 4 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY5413-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityuniversal current
5SY5413-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY5413-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SY5413-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY5413-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY5413-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.4 W

Product details

The 880 V DC rating is the maximum operating voltage, not the breaking capacity voltage; for DC circuits the 10 kA figure governs.

Mounting & integration — DIN-rail, 4 MW, any orientation

Environmental & compliance — halogen-free, wide temperature range, IP20

Ambient operating range is -40 to 75 °C. Derating curve is specified per the table: at 60 °C the rated current is 11.02 A, so a panel running at elevated temperature must account for the reduction. Pollution degree 2, overvoltage category II.

Frequently asked questions

What is the breaking capacity of 5SY5413-7?

10 kA per IEC/EN 60898-2 and 10 kA per EN 60898-2 at DC.

Will 5SY5413-7 drop into a panel specified around 5SY4140-7?

Both are 4-pole SENTRON MCBs with the same 4 MW footprint, so the physical swap is direct. The 5SY5413-7 is a 13 A C-curve; the 5SY4140-7 is a different rating/curve — verify the branch-circuit ampacity before substitution.

What compliance documentation is available for 5SY5413-7?

The part is certified to IEC/EN 60898-2 and UL 1077. As a SENTRON product it carries the manufacturer's standard declarations (RoHS, REACH) — request the specific certificate with your RFQ.

Where can I buy 5SY5413-7?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
5SY5413-7