Siemens 5SY6006-6KL — 1-Pole MCB (DIN Rail)

Siemens 5SY6006-6KL SENTRON MCB, 1P+N, B Curve, 6 A, 6 kA

MPN5SY6006-6KL

Siemens SENTRON 5SY6006-6KL miniature circuit breaker, 1P+N, B tripping characteristic, 6 A rated current, 6 kA breaking capacity at 230 V AC, 18 mm width, standard rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6006-6KL — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY6006-6KL — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SY6006-6KL — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.24 V
SealableYes
5SY6006-6KL — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

Siemens SENTRON 5SY6006-6KL — B-curve MCB, 1P+N, 6 A, 6 kA

Rated 6 A with B tripping characteristic, breaking 6 kA at 230 V AC. The 1P+N configuration switches both phase and neutral. IP20 rating with connected conductors.

B-curve selectivity and coordination

The B characteristic (3–5× In) is the most selective for resistive and light inductive loads. Compared to a C-curve breaker (5–10× In) in the same 6 A rating, the B curve will trip sooner on moderate overloads, which is desirable for protecting long cable runs or sensitive loads but means less tolerance for motor or transformer inrush. For a panel already specified around a C-curve device like the 5SY6008-7, swapping to this B-curve 5SY6006-6KL requires checking the downstream load's starting current — the B curve may nuisance-trip on a load that the C curve handled.

Tightening torque is 2.0 to 2.5 N·m (17.7 to 22.1 lbf·in). The terminals are touch-protected per the product feature. Both top and bottom terminals are non-combined (independent clamping per conductor). Strip length for stranded conductors follows standard practice — 12 to 14 mm is typical for this terminal class.

Frequently asked questions

Does 5SY6006-6KL switch the neutral?

Yes, the 1P+N configuration switches both the phase conductor and the neutral conductor. The neutral pole is on the left side of the unit.

What conductor sizes does the 5SY6006-6KL accept?

The screw terminals accept solid or stranded conductors from 0.75 mm² up to 16 mm².