Skip to main content
Siemens 5SY6020-6KL — 1-Pole MCB (DIN Rail)

Siemens 5SY6020-6KL SENTRON MCB, 1P+N B 20 A, 6 kA

MPN5SY6020-6KL

Siemens SENTRON 5SY6020-6KL miniature circuit breaker, 1-pole+N, B-curve, 20 A rated, 6 kA breaking capacity at 230 V AC, 18 mm width, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6020-6KL — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY6020-6KL — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SY6020-6KL — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.24 V
SealableYes
5SY6020-6KL — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY6020-6KL is a SENTRON miniature circuit breaker (MCB) with a 1-pole+N configuration, B-curve tripping characteristic, rated 20 A at 230 V AC, and a 6 kA breaking capacity per EN 60898. This is the current-production variant — lifecycle stage is active, so it's the standard line-item for new panels and BOM replacements alike. The 1P+N form factor switches both line and neutral, with the neutral pole switching but not protecting; the neutral conductor is disconnected when the breaker is off, which matters for isolation during panel service.

Screw terminals with a specified torque of 2.0–2.5 N·m (17.7–22.1 lbf·in). The top and bottom terminals are not combined (separate entry points for line and load), which is standard for this class.

Rated for ambient temperatures from -25 to +45 °C during operation, with periodic excursions to +55 °C at up to 95% relative humidity. Storage range is wider: -40 to +75 °C. Halogen-free and silicon-free construction, which matters for clean-room or sensitive electronics environments where outgassing is a concern. Vibration-resistant per IEC 60068-2-6. Overvoltage category III, so it's rated for fixed-installation distribution boards (not just downstream equipment).

Frequently asked questions

What is the breaking capacity of 5SY6020-6KL?

Rated 6 kA at 230 V AC per EN 60898. That's the standard breaking capacity for residential and light commercial distribution boards — sufficient for most final subcircuits where the prospective short-circuit current stays under 6 kA.

Will 5SY6020-6KL drop into a panel specified for 5SY6020-6?

Yes — same 18 mm width, same DIN-rail mount, same terminal range, same B-curve and current rating. The -6KL suffix denotes the specific combination of 1P+N poles and the left-side neutral position, but the physical footprint and electrical ratings are identical to the base 5SY6020-6 family. No rewiring or panel modification needed.

How do I get current pricing and availability for 5SY6020-6KL?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What compliance documentation does Siemens provide for 5SY6020-6KL?

The MCB carries a 6 kA rating per EN 60898, overvoltage category III, and is halogen-free and silicon-free. The SENTRON series typically includes CE marking, RoHS compliance, and manufacturer declarations — request the specific declaration of conformity or material compliance sheet with your RFQ.

MPN
5SY6020-6KL