Siemens 5SY6025-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY6025-6 SENTRON MCB, 1P+N, B-25A, 6kA

MPN5SY6025-6

Siemens SENTRON miniature circuit breaker, 1P+N, B-25 A, 6 kA, 230 V AC, 1 MW, standard-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6025-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY6025-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)6 kA
Overvoltage categoryIII
5SY6025-6 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.24 V
SealableYes
5SY6025-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY6025-6 SENTRON miniature circuit breaker

The Siemens 5SY6025-6 is a SENTRON miniature circuit breaker (MCB) rated at 25 A with a B tripping characteristic, 1P+N poles, and a 6 kA breaking capacity per EN 60898 at 230 V AC.

The 25 A rating at 230 V AC gives a maximum switched power of roughly 5.75 kW for single-phase loads; the 1 MW figure in the description likely reflects a per-pole or system-level labeling convention, not a continuous load limit — size your downstream load to the 25 A continuous rating. The B characteristic means magnetic trip occurs at 3–5× In (75–125 A), so it avoids nuisance trips on capacitor-switching or motor-start inrush but clears fast on a hard short. Terminals accept solid or stranded conductors from 0.75 to 16 mm², with a tightening torque of 2.0–2.5 N·m (17.7–22.1 lbf·in). The 1P+N configuration switches both phase and neutral, with neutral switching confirmed as a product function — important for applications requiring disconnection of the neutral conductor. Ambient temperature range is -25 to +45 °C, with periodic excursions to +55 °C at 95% humidity; derate the continuous current if the enclosure ambient exceeds 45 °C per the manufacturer's thermal curve.

Frequently asked questions

What is the closest functional second-source for the 5SY6025-6?

The 5SL6006-7 is a peer MCB in the same SENTRON family, but it carries a C tripping characteristic — verify the trip curve matches your circuit's inrush profile before substituting.

Will the 5SY6025-6 drop into a panel specified around the 5SL6006-7 without rewiring?

Both share the same 18 mm width, standard-rail mount, and terminal range (0.75–16 mm²), so the physical fit and wiring are identical — the difference is the trip curve (B vs C), not the footprint.

MPN
5SY6025-6