Skip to main content
Siemens 5SY6040-6 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SY6040-6 MCB, 1P+N, B 40 A, 6 kA

MPN5SY6040-6

Siemens SENTRON miniature circuit breaker, 1P+N, B-curve, 40 A, 6 kA breaking capacity per EN 60898, 1 MW width, compact design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6040-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SY6040-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SY6040-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodstandard rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6040-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What the ratings mean for fit

The Siemens SENTRON 5SY6040-6 is a 1P+N miniature circuit breaker with a B tripping characteristic, rated 40 A at 30 °C and 230 V AC, with a 6 kA breaking capacity per EN 60898. That B-curve means it trips between 3× and 5× rated current — designed for resistive and light inductive loads like lighting circuits, small heaters, and control transformers in residential and infrastructure panels. The 6 kA interrupting rating is the maximum fault current it can safely clear at 230 V; for most domestic and light commercial distribution boards this is sufficient, but verify your prospective short-circuit current at the installation point. The 1P+N pole design switches both line and neutral, with the neutral pole switching but not protected — common in single-phase final circuits where neutral isolation is required. At elevated ambient temperatures the breaker derates: 38 A at 40 °C, 37.2 A at 45 °C. That matters when the MCB sits in a crowded enclosure with other heat sources — the 40 A rating is only valid at 30 °C ambient. If your panel runs at 40 °C, the continuous load should not exceed 38 A.

Panel integration and mounting

The 5SY6040-6 snaps onto standard DIN rail (EN 60715) and occupies one modular width unit (18 mm). Mounting position is any — vertical, horizontal, or flat — which simplifies layout in tight enclosures. Installation depth is 70 mm; total depth including the breaker body is 76 mm. The IP20 rating (with connected conductors) means it is protected against finger contact but not water ingress — standard for indoor distribution boards. Touch protection is built in, so accidental contact with live terminals during maintenance is prevented.

Compliance and environmental

The breaker is halogen-free and silicon-free, which matters for clean-room or sensitive electronics environments where outgassing can cause contact corrosion or optical haze. It is sealable (can be locked in the OFF position for lockout/tagout). Vibration resistance per IEC 60068-2-6 is confirmed, so it holds up in transport or near rotating machinery. Pollution degree 2 and overvoltage category III suit fixed installations in residential and commercial buildings.

Frequently asked questions

What is the breaking capacity of 5SY6040-6?

6 kA per EN 60898 at 230 V AC.

What is the closest functional second-source for 5SY6040-6?

The 5SL6016-7KL is a similar Siemens SENTRON 1P+N B-curve MCB, but verify the rated current and breaking capacity against your specific load — the 5SY6040-6 is rated 40 A / 6 kA.

Where can I buy 5SY6040-6?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
5SY6040-6