Skip to main content
Siemens 5SY6102-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6102-7CC SENTRON MCB, 1P C-curve 2 A, 6 kA

MPN5SY6102-7CC

Siemens SENTRON 5SY6102-7CC, 1-pole miniature circuit breaker, C-curve, 2 A rated, 6 kA breaking capacity per EN 60898, 440 V AC max, 18 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6102-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY6102-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6102-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6102-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY6102-7CC is a SENTRON miniature circuit breaker (MCB) — a 1-pole unit with a C-curve tripping characteristic, rated 2 A at 440 V AC single-phase or multi-phase, and a 6 kA breaking capacity per EN 60898. That C-curve means it's designed for moderate inrush loads like motor starters or small transformers: the magnetic trip activates between 5 and 10 times rated current, so it holds through a brief start-up surge but clears a hard fault fast. The 6 kA rating is the maximum prospective fault current it can safely interrupt at 440 V AC — enough for most sub-distribution boards in commercial or light industrial panels.

Panel fit and environmental range

Width is 18 mm (one modular unit), depth 76 mm, height 90 mm. Snaps onto DIN rail via the quick-assembly system; mounting position is any orientation. The IP20 rating (with connected conductors) is standard for enclosed distribution boards — not for wet or outdoor locations. Ambient temperature range is -40 °C to 75 °C, with derated current values above 35 °C: 1.88 A at 40 °C, 1.82 A at 45 °C, 1.75 A at 50 °C, 1.68 A at 55 °C. Pollution degree 3 and overvoltage category III suit it for fixed installations where transient overvoltages are expected.

Frequently asked questions

Where can I buy 5SY6102-7CC and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is 5SY6102-7CC's listed depth (76 mm) on this component line?

The depth is 76 mm, with an installation depth of 70 mm. Width is 18 mm (1 modular unit), height 90 mm.

Will 5SY6102-7CC drop into a panel that was specified around 5SY4101-7CV without rewiring?

Both are 1-pole, 18 mm wide MCBs on DIN rail, so the physical footprint is identical. The 5SY6102-7CC is a C-curve 2 A unit; the 5SY4101-7CV is a different rating and curve — check the specific load and trip coordination before swapping. No rewiring needed for the same busbar position if ratings match.

MPN
5SY6102-7CC