Skip to main content
Siemens 5SY6106-6CC

Siemens 5SY6106-6CC SENTRON MCB, 1P B-Char, 6 kA

MPN 5SY6106-6CC

Siemens SENTRON 5SY6 series, miniature circuit breaker, 1-pole, B characteristic, 6 kA (EN 60898), 230/400 VAC, 72 VDC, 1 MW width, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY6106-6CC specifications
ParameterValue
Poles1
IP ratingIP20
MountingQuick assembly system
Temp operating max75 °C
Temp operating min55 °C
Depth76 mm
Width18 mm
Height90 mm
Energy limitation class3

Product details

Siemens 5SY6106-6CC — SENTRON 1-Pole MCB, B Characteristic, 6 kA

The Siemens 5SY6106-6CC is a SENTRON-series miniature circuit breaker (MCB) in active current production. It's a 1-pole unit with B tripping characteristic, rated 6 kA breaking capacity per EN 60898 at 230/400 VAC (50/60 Hz) and 72 VDC maximum. The B curve means it trips at 3–5× rated current — standard for resistive and general-purpose loads where you want fast protection without nuisance trips from inrush.

What the ratings mean for your panel

The 6 kA breaking capacity (per EN 60898) is the maximum prospective fault current this MCB can safely interrupt at rated voltage. For UL 1077 / CSA C22.2 No. 235 installations, the same unit carries a 5 kA interrupting rating — check which standard governs your panel's SCCR study. Pollution degree 3 (conductive pollution or dry non-conductive that becomes conductive) and overvoltage category III suit it for fixed-installation distribution boards, not just final circuits. Temperature derating matters here: the MCB is rated for ambient -40 °C to 75 °C, but the surrounding humidity must stay below 95% at 55 °C, 55% at 70 °C, and 35% at 75 °C. If your panel runs hot near the upper limit, the thermal-magnetic trip curve shifts — account for it in coordination studies.

Mounting and integration

Snaps onto DIN rail via the quick-assembly system, occupying 1 modular width unit (18 mm). Mounting position is unrestricted — vertical, horizontal, upside-down — which helps when panel layout is tight. Combined terminals top and bottom accept supply from either end. Installation depth behind the panel is 70 mm; overall depth is 76 mm. IP20 with connected conductors means it's protected against solid objects over 12 mm but not against water — keep it inside a closed enclosure.

MPN