Skip to main content
Siemens 5SY6110-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6110-7CC SENTRON MCB, 1P C-Curve, 6 kA, 1 MW

MPN5SY6110-7CC

Siemens SENTRON 5SY6110-7CC, 1-pole miniature circuit breaker, C tripping characteristic, 6 kA breaking capacity per EN 60898, 1 modular width unit.

$27.77Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6110-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY6110-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6110-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6110-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY6110-7CC is a 1-pole miniature circuit breaker from the SENTRON family, carrying a C tripping characteristic and rated 6 kA breaking capacity per EN 60898 at 230/400 V AC. The single modular width (18 mm) fits one DIN-rail slot, so it packs into a crowded panel without stealing space from adjacent devices.

The 5 kA rating per UL 1077 and CSA C22.2 No. 235 means it also qualifies for North American supplementary-protection applications — useful if the panel ships to a dual-standard site. Temperature range spans -40 °C to 75 °C, with humidity derating above 55 °C: max 95% RH at 55 °C, dropping to 35% at 75 °C. That matters if the breaker lives near a steam line or a drying oven — the surrounding air's moisture load determines whether the internal arc-quenching path stays reliable. Vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) covers the usual pump and compressor panels; no special dampening needed. The 1-pole design switches the line only — no neutral pole, so it's for single-phase branch circuits where the neutral is common-bonded. Sealable means the toggle can be locked in the off position for lockout/tagout without an accessory padlock hasp.

Mounting position is any orientation, so it works in horizontal busbar drops or vertical panel layouts. The halogen-free and silicon-free construction avoids corrosive off-gassing in a sealed panel and won't contaminate sensitive contacts in relay or PLC cabinets nearby.

Frequently asked questions

How do I get current pricing and availability for 5SY6110-7CC?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; the part is sourced to order through independent distribution channels.

Will 5SY6110-7CC drop into a panel specified around 5SY4101-7CV without rewiring?

Both are 1-pole, 1-modular-width (18 mm) SENTRON MCBs with the same DIN-rail footprint and terminal layout, so the mechanical swap is direct. The difference is breaking capacity: 5SY6110-7CC carries 6 kA per EN 60898, while the 5SY4101-7CV is a 4.5 kA variant. If the panel's available fault current is under 4.5 kA, the swap is electrically equivalent; above that, verify the 5SY6110-7CC's higher rating doesn't create a coordination issue with downstream devices.

What compliance documentation does this brand provide for 5SY6110-7CC?

The SENTRON series carries EN 60898 certification for the 6 kA rating, plus UL 1077 and CSA C22.2 No. 235 for North American supplementary protection. The part is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations.

MPN
5SY6110-7CC