Siemens 5SY6111-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY6111-7 SENTRON MCB, 1P C-Curve, 6kA/30kA

MPN5SY6111-7
Active

Siemens SENTRON 5SY6111-7, 1-pole miniature circuit breaker, C-curve, 6 kA per EN 60898 / 30 kA per IEC 60947-2, 18 mm width, IP20.

$7.28Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6111-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY6111-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6111-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6111-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Breaking capacity — what the two ratings mean

The 6 kA rating under EN 60898-1 is the standard for household and similar installations — it's what you'd see on a domestic consumer unit spec. That dual rating lets you use the same 5SY6111-7 across a light commercial board and a heavy industrial panel without swapping parts.

At 18 mm wide (1 MW), it occupies one slot on a standard DIN rail. Mounting position is any orientation, so you can lay it sideways in a shallow enclosure if needed.

Environmental and construction notes

Rated for -40 °C to 75 °C ambient, with humidity derating above 55 °C (95% RH at 55 °C, dropping to 35% at 75 °C). Halogen-free and silicon-free construction — relevant if you're putting this in a clean room or a sealed enclosure where outgassing matters. Sealable terminals let you lock the cover after commissioning to prevent tampering.

Frequently asked questions

What is the breaking capacity of the 5SY6111-7?

6 kA per EN 60898-1 and 30 kA per IEC 60947-2 at 400 V AC. The 30 kA rating also applies at 60 V DC per IEC 60947-2.

Will the 5SY6111-7 drop into a panel specified around the 5SY4140-7?

Both are 1-pole SENTRON MCBs on an 18 mm footprint, so the mechanical fit is identical. The difference is the breaking capacity: the 5SY6111-7 carries the higher 30 kA (IEC 60947-2) rating versus the 5SY4140-7's lower interrupting rating. If the panel's fault-current study calls for 30 kA, the 5SY6111-7 is the correct drop-in; if the spec was written around a lower-rated breaker, verify the fault level before substituting.

Where can I buy the 5SY6111-7 and how is it quoted?

Sourced through independent distribution channels. Submit an RFQ for current pricing and availability — both are confirmed at quote time, not on a static listing.

What compliance documentation does Siemens provide for the 5SY6111-7?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, UL 1077, and CSA C22.2 No. 235. Declaration of conformity and test reports are available with the shipment.

MPN