Siemens 5SY6118-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY6118-7 SENTRON MCB, 1P C-15A, 6kA/15kA

MPN5SY6118-7
Active

Siemens SENTRON 5SY6118-7, 1-pole C-curve miniature circuit breaker, 15 A rated current, 6 kA (EN 60898) / 15 kA (IEC 60947-2) breaking capacity, 18 mm wide, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY6118-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry

Electrical & Protection

5SY6118-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII

Mounting & Connection

5SY6118-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes

Environmental

5SY6118-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What it is and where it fits

The Siemens SENTRON 5SY6118-7 is a single-pole miniature circuit breaker (MCB) with C-curve tripping characteristic, rated 15 A at AC. It snaps onto a DIN rail — 18 mm wide, one modular unit — and mounts in any position, so panel layout is flexible. The IP20 rating (with connected conductors) means it belongs inside a closed enclosure, not exposed to washdown.

Breaking capacity — what it means for your panel

This breaker carries two breaking-capacity ratings: 6 kA per EN 60898 (the household / light commercial standard) and 15 kA per IEC 60947-2 (the industrial standard). The 15 kA figure governs fault-current handling in industrial panels — it safely interrupts a short-circuit up to that level without welding contacts or cascading failure upstream. The same 15 kA rating applies for DC circuits per IEC 60947-2, so it works on DC branches too.

Thermal derating — don't oversize the bus

The 15 A rating holds at 35 °C ambient. At 40 °C it derates to 14.28 A; at 50 °C to 13.53 A; at 55 °C to 13.12 A. If the panel runs hot — say, 50 °C inside a sealed enclosure — expect the breaker to carry about 10 % less than its nameplate. Plan the branch load accordingly.

Frequently asked questions

Where can I buy the 5SY6118-7?

It is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 5SY6118-7?

6 kA per EN 60898 and 15 kA per IEC 60947-2 for AC circuits; 15 kA for DC per IEC 60947-2.

Does the 5SY6118-7 replace the 5SY7210-7CC?

No — this is a different current rating (15 A C-curve vs the 5SY7210-7CC's 10 A C-curve). They share the same SENTRON family and DIN-rail footprint, but the breaker size must match the branch circuit design; they are not drop-in substitutes without re-evaluating the load.