Siemens 5SY6132-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6132-7CC SENTRON MCB, 1P C-Curve 32 A 6 kA

MPN5SY6132-7CC

Siemens SENTRON 5SY6132-7CC, 1-pole miniature circuit breaker, C-curve, 32 A rated current, 6 kA breaking capacity per EN 60898, 5 kA per UL 1077, 400 V AC, 1 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6132-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SY6132-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SY6132-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6132-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY6132-7CC — SENTRON 1P C-Curve 32 A MCB

It breaks 6 kA per EN 60898 at 400 V AC and carries a 5 kA interrupting rating under UL 1077 and CSA C22.2 No. 235 — so it covers both IEC and North American panel specs on the same BOM line.

Mounting position any, so vertical or horizontal busbar feeds work. IP20 with connected conductors; pollution degree 3 for industrial environments. Touch protection built in.

Environmental and compliance range

Humidity derating: 95% RH at 55 °C, 55% at 70 °C, 35% at 75 °C — relevant for outdoor cabinets in hot-humid climates or near washdown zones. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Frequently asked questions

What is the closest functional second-source to 5SY6132-7CC?

The 5SY7140-8CC is a 1-pole C-curve MCB from the same SENTRON family but rated 40 A — same 18 mm width, same 6 kA breaking capacity. It drops into the same DIN-rail footprint without rewiring, but the 8 A difference means you must verify the load's full-load current and the upstream protective device coordination before swapping.

Will 5SY6132-7CC drop into a panel specified around 5SY7140-8CC without rewiring?

Yes, physically — both are 1-module-width (18 mm) SENTRON breakers with the same DIN-rail clip and terminal layout. The only difference is the 32 A vs 40 A rating and the C-curve. No rewiring needed if the circuit load is ≤32 A and the coordination study allows the lower rating.

What compliance documentation does Siemens provide for 5SY6132-7CC?

The breaker carries IEC 60898 (6 kA) and UL 1077 / CSA C22.2 No. 235 (5 kA) ratings. It is halogen-free and silicon-free. Standard Siemens declarations for RoHS and REACH are available on request with the order documentation.

How do I get current pricing and availability for 5SY6132-7CC?

Submit an RFQ through the site. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time — no automated stock figure on this listing.

MPN
5SY6132-7CC