Skip to main content
Siemens 5SY6150-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SY6150-7CC SENTRON MCB, 50 A, 1P, C-Curve, 6 kA

MPN5SY6150-7CC

Siemens SENTRON 5SY6150-7CC miniature circuit breaker, 1-pole, 50 A, C-curve, 6 kA breaking capacity per EN 60898, 440 V AC, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6150-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY6150-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY6150-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY6150-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY6150-7CC SENTRON MCB — 50 A, C-Curve, 6 kA

The Siemens 5SY6150-7CC is a 1-pole SENTRON miniature circuit breaker rated 50 A with a C tripping characteristic and a 6 kA breaking capacity per EN 60898, designed for 440 V AC systems. It occupies a single 18 mm modular width on the DIN rail, making it a direct fit for standard distribution boards and sub-panels where overcurrent and short-circuit protection is needed for lighting, socket outlets, or small motor circuits.

What the ratings mean for fit

The 50 A rating at 35 °C is the base thermal rating; at 40 °C it derates to 45.95 A, at 45 °C to 43.75 A, at 50 °C to 41.45 A, and at 55 °C to 39.05 A. If the panel ambient runs above 35 °C, the connected load must be reduced accordingly — a 40 A continuous load at 50 °C ambient is fine, but a 48 A load would nuisance-trip. The C-curve means magnetic trip occurs at 5–10× In (250–500 A), suited for moderate inrush loads like small motors or capacitive lighting ballasts. Breaking capacity is 6 kA per EN 60898 — adequate for residential and light commercial panels where the prospective short-circuit current stays under that threshold. For industrial panels with higher fault current, verify the available fault current at the installation point. Overvoltage category III and pollution degree 3 confirm suitability for fixed-installation distribution boards.

Mounting and integration

Snap-on mounting to DIN rail via the quick assembly system; any mounting position allowed. Installation depth is 70 mm, overall depth 76 mm. Width is 18 mm, one modular unit. Combined terminals top and bottom accept busbar and cable connections. IP20 with connected conductors — suitable for enclosed distribution boards, not for wet or washdown areas.

Frequently asked questions

What are the key ratings of the 5SY6150-7CC?

Rated 50 A at 35 °C, C-curve, 6 kA breaking capacity per EN 60898, 440 V AC, 1-pole, 18 mm wide.

What is the 5SY6150-7CC depth?

Overall depth is 76 mm; installation depth is 70 mm.

Will the 5SY6150-7CC fit a panel designed for the 5SY7210-7CC?

Yes, both are 18 mm wide 1-pole SENTRON MCBs with the same DIN-rail footprint and terminal layout. The 5SY6150-7CC drops in without rewiring, provided the 6 kA breaking capacity (vs the 5SY7210-7CC's higher rating) is adequate for the site's fault current.

How can I get pricing and availability for the 5SY6150-7CC?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our independent distribution channels.

MPN
5SY6150-7CC