Skip to main content
Siemens 5SY6204-6CC — 2-Pole MCB (DIN Rail)

Siemens 5SY6204-6CC SENTRON MCB, B-Curve 2-Pole, 6 kA

MPN5SY6204-6CC

Siemens SENTRON 5SY6204-6CC, B-curve miniature circuit breaker, 2-pole, 6 kA breaking capacity per EN 60898 at 400 VAC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6204-6CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6204-6CC — Electrical
ParameterValue
Number of poles2
5SY6204-6CC — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY6204-6CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY6204-6CC — Environmental
ParameterValue
Pollution degree3
5SY6204-6CC — Specifications
ParameterValue
At AC rated value400 V
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value440 V
Energy Limitation Class3

Product details

B-curve 2-pole MCB for general-purpose protection

The Siemens SENTRON 5SY6204-6CC is a B-curve miniature circuit breaker with 2 poles, rated 6 kA breaking capacity per EN 60898 at 400 VAC. At 440 VAC in single- or multi-phase operation, the same 6 kA rating holds, so it covers 400/440 V panels without derating. The 2-pole design switches both phase conductors but leaves the neutral unswitched — typical for single-phase branch circuits in European-style distribution boards. Rated for 50/60 Hz AC supply only, with a maximum DC operating voltage of 72 V — not a DC-rated breaker for solar or battery strings.

Panel fit and environmental range

The 2 MW (modular width) footprint matches standard DIN-rail enclosures — no special adapters needed. Ambient temperature range spans -40 °C to 75 °C, with humidity derating: 95% RH up to 55 °C, 55% RH up to 70 °C, and 35% RH at 75 °C. Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz — enough for machine-mounted panels on pumps or conveyors.

Frequently asked questions

Will 5SY6204-6CC drop into a panel specified for 5SY4304-7CV?

Yes, the physical footprint and DIN-rail mounting are identical — both are 2-pole, 2 MW SENTRON MCBs. The only difference is the trip curve (B vs C), so the swap is mechanically compatible but electrically must match the load's inrush characteristics.

MPN
5SY6204-6CC