Siemens 5SY6204-7CC — 2-Pole MCB (DIN Rail)

Siemens 5SY6204-7CC SENTRON MCB, 2P C-4A 6kA, 440V AC

MPN5SY6204-7CC

Siemens SENTRON 5SY6204-7CC, 2-pole miniature circuit breaker, C tripping characteristic, 4 A rated current, 6 kA breaking capacity per EN 60898, 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6204-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6204-7CC — Electrical
ParameterValue
Number of poles2
5SY6204-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY6204-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY6204-7CC — Environmental
ParameterValue
Pollution degree3
5SY6204-7CC — Specifications
ParameterValue
Energy Limitation Class3

Product details

What it is and what it does

The Siemens 5SY6204-7CC is a 2-pole miniature circuit breaker (MCB) from the SENTRON family, carrying a C tripping characteristic and rated at 4 A for AC circuits at 50/60 Hz up to 440 V. Its breaking capacity of 6 kA per EN 60898 means it can safely interrupt short-circuit faults up to that level in residential or light industrial distribution boards. The C-curve (tripping between 5 and 10 times rated current) suits it for loads with moderate inrush — think small motor starters, lighting groups, or control transformers where the start-up spike is higher than a resistive heater but not as aggressive as a heavy motor direct-on-line start.

Mounting and panel fit

Snaps onto standard DIN rail via the quick-assembly system; occupies 2 modular width units (36 mm total). Mounting position is unrestricted — vertical, horizontal, upside-down, whatever the enclosure layout demands. Installation depth is 70 mm behind the panel face, with an overall depth of 76 mm including the front profile. The combined top and bottom terminals accept wiring from either direction, which saves time when daisy-chaining multiple breakers on a busbar.

Environmental and compliance

Rated for ambient temperatures from -40 °C to 75 °C, with a derating curve that drops the continuous current from 4 A at 35 °C to 3.37 A at 55 °C — factor that in if the breaker sits in a hot cabinet next to transformers or drives. Pollution degree 3 (conductive pollution or dry non-conductive that becomes conductive with condensation) and overvoltage category III (fixed installation downstream of the main distribution board) match typical panel environments. IP20 with connected conductors — fine inside a closed enclosure, not for wet or dusty locations. Halogen-free and silicon-free construction, sealable for tamper-evident applications.

Frequently asked questions

What is 5SY6204-7CC's listed depth (76 mm) on this component line?

The overall depth is 76 mm; the installation depth behind the panel face is 70 mm.

What is 5SY6204-7CC's listed width (36 mm) on this component line?

Width is 36 mm, which corresponds to 2 modular width units on standard DIN rail.