Skip to main content
Siemens 5SY6205-8 — 2-Pole MCB (DIN Rail)

Siemens 5SY6205-8 SENTRON MCB, 2P D 0.5 A, 6/30/15 kA

MPN5SY6205-8

Siemens SENTRON 5SY6 series, miniature circuit breaker, 2-pole, D tripping characteristic, 0.5 A rated current, 400 V AC, 72 V DC max, breaking capacities 6 kA (EN 60898) / 30 kA (IEC 60947-2) / 15 kA DC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6205-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6205-8 — Electrical
ParameterValue
Number of poles2
5SY6205-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY6205-8 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

The 5SY6205-8 is a 2-pole miniature circuit breaker from the Siemens SENTRON 5SY6 series, rated 0.5 A with a D tripping characteristic. On a 400 V AC line (rated value, 50/60 Hz), it clears faults at 6 kA per EN 60898 for standard branch-circuit protection, and up to 30 kA per IEC 60947-2 when used in industrial distribution with higher prospective fault current. The 0.5 A rating is the continuous thermal current; any sustained overload above that will trip the bimetal element on the thermal curve. Terminal capacity accepts solid or stranded conductors from 0.75 to 35 mm² — enough for the supply side even with the low 0.5 A rating, useful when the breaker is fed from a larger upstream conductor. IP20 with connected conductors; touch protection is built in.

Deployment context

Rated for mechanical engineering and industrial environments. The D-curve and 30 kA SCCR make it a fit for machine-tool control panels, conveyor distribution boards, and pump starter enclosures where the breaker must ride through motor inrush without nuisance tripping. Halogen-free and silicon-free construction suits clean-room or coated-panel requirements.

Frequently asked questions

What is the breaking capacity of 5SY6205-8?

6 kA per EN 60898 for standard branch-circuit duty, 30 kA per IEC 60947-2 for industrial distribution, and 15 kA at 72 V DC per IEC 60947-2. Under UL 1077 / CSA C22.2 No. 235 the AC rating is 5 kA.

Will 5SY6205-8 drop into a panel specified for 5SY6602-8?

Both are 2-pole SENTRON 5SY6 breakers with the same 36 mm width and DIN-rail mounting, so the mechanical fit is identical. The difference is the rating: 5SY6205-8 is 0.5 A D-curve; 5SY6602-8 is a different current/curve variant. No rewiring of the bus or DIN rail is needed if the ampacity matches the circuit design.

What compliance documentation is available for 5SY6205-8?

The breaker carries approvals per EN 60898, IEC 60947-2, UL 1077, and CSA C22.2 No. 235. It is halogen-free and silicon-free. RoHS and REACH declarations are standard for Siemens SENTRON products; request the specific declaration with your RFQ.

How do I get pricing and availability for 5SY6205-8?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock position are confirmed at quote time.

MPN
5SY6205-8