Skip to main content
Siemens 5SY6205-8CC — 2-Pole MCB (DIN Rail)

Siemens 5SY6205-8CC SENTRON MCB, 0.5 A D-Curve, 2-Pole

MPN5SY6205-8CC

Siemens SENTRON 5SY6 series, 2-pole miniature circuit breaker, 0.5 A rated current, D tripping characteristic, 400 V AC, 6 kA breaking capacity per EN 60898, 2 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6205-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6205-8CC — Electrical
ParameterValue
Number of poles2
5SY6205-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY6205-8CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

Siemens 5SY6205-8CC — 0.5 A D-Curve MCB for High-Inrush Loads

The Siemens 5SY6205-8CC is a SENTRON 5SY6 series miniature circuit breaker rated 0.5 A at 400 V AC with a D tripping characteristic. Breaking capacity is 6 kA per EN 60898 (IEC 60898) and 5 kA per UL 1077 / CSA C22.2 No. 235, which covers the standard industrial panel fault-current range for a 0.5 A branch; in a 400 V distribution board with a transformer upstream, this breaker clears a bolted fault up to 6 kA without the arc transferring to the busbar. The 2-pole design occupies 2 MW (36 mm) on the DIN rail, with a depth of 76 mm and an installation depth of 70 mm.

Terminal Capacity and Environmental Range

Terminals accept solid and stranded conductors from 0.75 mm² up to 35 mm² — enough for a 0.5 A circuit where the loop impedance often dictates a larger cross-section than the load current needs; the screw terminals torque to 2.5–3.5 N·m, and combined terminals (top and bottom) allow daisy-chaining without separate distribution blocks. Ambient operating range is -25 °C to +55 °C, with storage from -40 °C to +75 °C; humidity tolerance is 95% at 55 °C, derating to 35% at 75 °C — the breaker is at home in a non-condensing panel in a warm factory, but not in a sealed cabinet with a heat source directly below it.

Frequently asked questions

What conductor sizes does the 5SY6205-8CC accept?

Solid and stranded conductors from 0.75 mm² up to 35 mm², with screw terminals torqued to 2.5–3.5 N·m.

Will the 5SY6205-8CC drop into a panel specified around the 5SY7140-8CC?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint (36 mm wide, 76 mm deep), but the 5SY6205-8CC is a 0.5 A D-curve and the 5SY7140-8CC is a higher-current variant — the physical fit is identical, but the trip rating and curve must match the circuit design.

MPN
5SY6205-8CC