Skip to main content
Siemens 5SY6208-8 — 2-Pole MCB (DIN Rail)

Siemens 5SY6208-8 SENTRON MCB, 2-Pole D-Curve 8A, 6/15 kA

MPN5SY6208-8

Siemens SENTRON 5SY6 series, miniature circuit breaker, 2-pole, D tripping characteristic, 8 A rated current, 400 V AC, breaking capacity 6 kA per EN 60898 / 15 kA per IEC 60947-2.

$55.68Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6208-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6208-8 — Electrical
ParameterValue
Number of poles2
5SY6208-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY6208-8 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY6208-8 — Environmental
ParameterValue
Pollution degree3

Product details

What the ratings mean for your panel

The Siemens 5SY6208-8 is a 2-pole miniature circuit breaker from the SENTRON 5SY6 family, rated 8 A at 400 V AC. The D tripping characteristic means it tolerates high inrush currents — typically 10–20× rated current — making it the right choice for motor, transformer, or welding-equipment branch circuits where a B- or C-curve would nuisance-trip on startup. Breaking capacity is 6 kA per EN 60898 for general distribution and 15 kA per IEC 60947-2 for industrial panel applications, so it handles fault currents up to that level without upstream coordination issues in most standard MCCs. At 2 modules wide (36 mm), it snaps onto DIN rail via the quick-assembly system and accepts top/bottom comb busbars — the combined terminal feature means you can feed a busbar through either end without extra adapters. Mounting position is any, and the IP20 rating (with conductors connected) is standard for enclosed panel gear.

Lifecycle and sourcing reality

Approvals include EN 60898, IEC 60947-2, UL 1077 and CSA C22.2 No. 235 — the UL/CSA supplementary-protector rating at 5 kA (480Y/277 V) covers North American panel builds. Halogen-free and silicon-free construction matters for high-reliability or clean-room environments where outgassing can contaminate contacts or optics.

Integration notes

Depth is 76 mm, installation depth 70 mm — check gland-plate clearance if back-panel wiring is tight. The 90 mm height and 36 mm width (2 width units) fit standard Siemens distribution boards and most third-party enclosures. Sealable cover option (yes) allows lockout/tagout compliance without an external hasp. Rated for ambient temperature from -40 °C to 75 °C, with humidity derating above 55 °C — suitable for unheated enclosures or outdoor cabinets in temperate climates. Pollution degree 3 and overvoltage category III are typical for fixed-installation industrial panels.

Frequently asked questions

What is the breaking capacity of 5SY6208-8?

6 kA per EN 60898 for general distribution, 15 kA per IEC 60947-2 for industrial panels, and 5 kA per UL 1077 / CSA C22.2 No. 235 for North American supplementary protection.

Where can I buy 5SY6208-8 and how is it quoted?

We source it through independent distribution channels and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SY6208-8 drop into a panel specified for 5SY6613-8?

Both are 2-pole SENTRON 5SY6 breakers with the same 36 mm width and DIN-rail mounting, so mechanical fit is identical. The difference is the tripping curve — 5SY6208-8 is D-curve (high inrush), while 5SY6613-8 is a different characteristic. Verify the branch-circuit inrush requirements before substituting.

MPN
5SY6208-8