Skip to main content
Siemens 5SY6210-6CC — 2-Pole MCB (DIN Rail)

Siemens 5SY6210-6CC SENTRON MCB, 2P B-Char 10A, 6kA

MPN5SY6210-6CC

Siemens SENTRON 5SY6 series miniature circuit breaker, 2-pole, B tripping characteristic, 10 A rated current, 6 kA breaking capacity at 400 V AC, 36 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6210-6CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6210-6CC — Electrical
ParameterValue
Number of poles2
5SY6210-6CC — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY6210-6CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY6210-6CC — Environmental
ParameterValue
Pollution degree3

Product details

The Siemens 5SY6210-6CC is a 2-pole miniature circuit breaker from the SENTRON 5SY6 series, designed for 400 V AC systems with a B tripping characteristic and a rated current of 10 A. Breaking capacity is 6 kA per EN 60898 at 400 V AC, and 5 kA per UL 1077 and CSA C22.2 No. 235 — enough for most secondary distribution panels in industrial environments. The 2-pole configuration (2P) switches both phase and neutral; no integral neutral switching (confirms neutral is not switched internally). Rated for any mounting position, with IP20 protection when conductors are connected.

Integration and compliance notes

Halogen-free and silicon-free construction suits sealed enclosures or clean-room adjacent panels where outgassing matters. Sealable for tamper-evident applications. Energy limiting class 3 — the MCB limits let-through energy well, aiding downstream coordination. Rated frequency 50/60 Hz. The part carries the designation code 5SY6CC and is listed for mechanical engineering and industry applications.

Frequently asked questions

Where can I buy the 5SY6210-6CC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings for this MCB?

Rated current 10 A, B tripping characteristic, 2-pole, 400 V AC, breaking capacity 6 kA per EN 60898 and 5 kA per UL 1077/CSA C22.2 No. 235.

Will the 5SY6210-6CC fit in a panel designed for the 5SY3132-6?

Both are 2-pole, 36 mm wide SENTRON MCBs with the same DIN-rail mounting and terminal layout, so they share the same panel footprint. However, the 5SY3132-6 has a different tripping characteristic and current rating — verify the BOM specs before substitution.

MPN