Skip to main content
Siemens 5SY6213-8CC — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SY6213-8CC MCB, 2P D 13A 6kA

MPN5SY6213-8CC

Siemens SENTRON 5SY6 series, miniature circuit breaker, 2-pole D-curve, 13 A, 6 kA (IEC 60898) / 5 kA (UL 1077), 400 V AC, 2-module width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6213-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY6213-8CC — Electrical
ParameterValue
Number of poles2
5SY6213-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY6213-8CC — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY6213-8CC — Environmental
ParameterValue
Pollution degree3

Product details

It breaks fault currents up to 6 kA per EN 60898 and 5 kA per UL 1077 / CSA C22.2 No. 235, so it coordinates with standard panelboard bus ratings in both IEC and North American installations. The D curve (10–20× In) handles high inrush loads — motor starters, small transformers, solenoid banks — without nuisance tripping on startup.

The 5SY6213-8CC occupies 2 width units (36 mm) on a DIN rail, with a depth of 76 mm and height of 90 mm. It snaps onto the quick-assembly mounting system and accepts conductors at both top and bottom combined terminals.

It operates from -40 °C to 75 °C, with humidity derating above 55 °C (95% RH at 55 °C, 55% at 70 °C, 35% at 75 °C). Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz — enough for machine-mounted panels on pumps or compressors.

Frequently asked questions

Where can I buy 5SY6213-8CC and how do I get a price?

The 5SY6213-8CC is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing.

What is 5SY6213-8CC's listed depth?

The listed depth is 76 mm, with an installation depth of 70 mm.

What is 5SY6213-8CC's listed width?

The width is 36 mm, which corresponds to 2 width units on a DIN-rail panel.

Will 5SY6213-8CC drop into a panel specified around 5SY6140-6CC without rewiring?

Both are 2-pole SENTRON 5SY6-series breakers on the same DIN-rail footprint, so the mechanical fit is identical. The difference is the rating: 5SY6140-6CC is a 40 A C-curve; 5SY6213-8CC is a 13 A D-curve. No rewiring needed if the panel bus and load match the 13 A D-curve rating.

What compliance documentation does Siemens provide for 5SY6213-8CC?

The breaker carries IEC 60898 (6 kA) and UL 1077 / CSA C22.2 No. 235 (5 kA) certifications. The manufacturer supplies RoHS and REACH declarations with the shipment.